High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis
نویسندگان
چکیده
OBJECTIVE To study the relevance of high-sensitive troponin measurements in the acute workup in patients admitted to the emergency department of a large university hospital due to syncope. METHODS In this retrospective study all patients admitted to the emergency department because of syncope of the Inselspital, University Hospital Bern between 01 August 2010 and 31 October 2012, with serial determination of high-sensitive troponin (baseline and three hours control) were included. Of all identified patients we obtained data on demographics, laboratory data, ECG as well as on outcome. A change in high-sensitive troponin in the three hours control of +/-30% compared to baseline was considered significant. RESULTS A total of 121 patients with a mean age of 67 years (SD 16) were included in the study. 79 patients (65%) were male and 42 (35%) were female. There was no significant difference in the median high sensitive-troponin level at baseline and in the three hours control (0.01 mcg/L [0.003 to 0.022] versus 0.011 mcg/L [0.003 to 0.022], p = 0.47). Median percent change in high-sensitive troponin level between baseline and control was 0% (-9.1 to 5). 51 patients (42%) had elevated high-sensitive troponin levels at baseline with 7 patients (6%) showing a dynamic of +/-30% change from the baseline measurement in the 3 hours control. 3 of these patients received coronary angiography due to the dynamic in high-sensitive troponin, none of whom needed intervention for coronary revascularization. CONCLUSIONS On basis of the current study, where no single patient took benefit from determination of high-sensitive troponin, measurement of cardiac troponins should be reserved for patients with syncope presenting with symptoms suggestive for the presence of an acute cardiac syndrome.
منابع مشابه
Cardiac enzyme in emergency medicine
Objective: Acute chest pain is an important and frequently occurring symptom in patients. Chest pain is often a sign of ischemic heart disease. Chest pain due to suspected Acute Coronary Syndrome (ACS) is responsible for a large and ijncreasing number of hospital attendances and admissions. Current practice for suspected ACS involves troponin testing 10–12 hours after symptom o...
متن کاملIncidence of pulmonary embolism in an emergency department cohort evaluated with a simple symptom-based diagnostic algorithm.
BACKGROUND Although complex scores were recommended for diagnosis of pulmonary embolism (PE), acceptance in clinical practice is limited. In our Emergency Department a symptom-based algorithm for patients with suspected PE including computed tomographic pulmonary angiography (CTPA) and D-dimer testing was implemented. PATIENTS AND METHODS The cases of 492 patients presenting with either chest...
متن کاملTroponin utilization in patients presenting with atrial fibrillation/flutter to the emergency department: retrospective chart review
BACKGROUND There are few recommendations about the use of cardiac markers in the investigation and management of atrial fibrillation/flutter. Currently, it is unknown how many patients with atrial fibrillation/flutter undergo troponin testing, and how positive troponin results are managed in the emergency department. We sought to look at the emergency department troponin utilization patterns. ...
متن کاملDiagnostic and prognostic significance of high sensitive troponin in chest pain.
BACKGROUND AND OBJECTIVES Chest pain is one of the most frequent presenting complaints among patients arriving to the Emergency Department. In this population, the prevalence of acute coronary syndrome is about 25% instead that of acute myocardial infarction ranges from 5 to 15%. The diagnostic challenge for the emergency physician is the early rule-in or rule out of acute myocardial infarction...
متن کاملCombined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: first experience in an emergency department of a general hospital
BACKGROUND The purpose of this observational study was to test the diagnostic performance of the Elecsys® troponin T high-sensitive system combined with copeptin measurement for early exclusion of acute myocardial infarction (MI) in clinical practice. METHODS Troponin T high-sensitive (diagnostic cutoff: <14 pg/mL) and copeptin (diagnostic cutoff: <14 pmol/L) levels were determined at admissi...
متن کامل