Prostate positioning errors associated with two automatic registration based image guidance strategies

نویسندگان

  • D. Ryan
  • C. Rivest
  • Terence A. Riauka
  • Albert D. Murtha
  • B. Gino Fallone
چکیده

Daily image guidance for helical tomotherapy prostate patients is based on the registration of pre-treatment megavoltage CT (MVCT) images and the original planning CT. The goal of registration, whether manual or automatic, is the overlap of the prostate; otherwise prostate misplacement may compromise the efficacy of treatment or lead to increased toxicity. A previous study demonstrated that without the aid of implanted fiducials, manual registration results in inaccurate prostate positioning. The objective of this work is to quantify prostate misplacement that results from automatic bone matching (BM) and image matching (IM) registration algorithms. 204 MVCT images from 8 high risk tomotherapy prostate patients were incorporated into this retrospective study. BM and IM registration algorithms--based on maximization of mutual information of bony anatomy only and the entire image, respectively--were used to independently register MVCT images to their respective planning images. A correlation coefficient based algorithm that uses known planning CT contour information was used for automatic prostate localization in each MVCT image. Daily prostate misplacement was determined by repositioning as calculated from the BM and the IM algorithms. Mean (+/- SD) and maximum 3D prostate positioning errors were 3.7 +/- 2.1 mm and 11.8 mm for bone matching and 4.6 +/- 2.3 mm and 11.5 mm for image matching. In terms of translational directions, IM would lead to prostate positioning error > or = 3 mm in any of the LR, AP or SI directions in 62% of treatment fractions. The corresponding value for BM is 51%. The values for positioning errors > or = 5 mm were 29% and 17% for IM and BM, respectively. This data suggests automatic daily image guidance for tomotherapy prostate patients should be based on bone matching instead of image matching.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model

Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...

متن کامل

A comparative assessment of prostate positioning guided by three-dimensional ultrasound and cone beam CT

BACKGROUND The accuracy of the Elekta Clarity™ three-dimensional ultrasound system (3DUS) was assessed for prostate positioning and compared to seed- and bone-based positioning in kilo-voltage cone-beam computed tomography (CBCT) during a definitive radiotherapy. METHODS The prostate positioning of 6 patients, with fiducial markers implanted into the prostate, was controlled by 3DUS and CBCT....

متن کامل

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC) patients immobilized by customized thermoplastic masks. Nine patients received weekly imaging sessions, for a total of 54, throughout treatment. Patients were first set up by matching lasers to surface mark...

متن کامل

Image quality enhancement in digital panoramic radiograph

One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009