Side effects of intraoral devices for OSAS treatment.

نویسندگان

  • Andressa Otranto de Britto Teixeira
  • Ana Luiza Ladeia Andrade
  • Rhita Cristina da Cunha Almeida
  • Marco Antonio de Oliveira Almeida
چکیده

INTRODUCTION Intraoral devices have increasingly assumed a key role in the treatment of obstructive sleep apnea syndrome, but there are limitations to their indication and side effects that result from their continuous use, as well as the use of the continuous positive airway pressure device. OBJECTIVES To evaluate the changes in dental positioning caused by the continuous use of mandibular advancement devices. METHODS A prospective longitudinal study with a sample of 15 patients, with evaluation of complete documentation after a mean time of 6.47 months, assessed changes in dental positioning due to the use of the Twin Block oral device for the treatment of patients with apnea. The following variables were evaluated: overjet, overbite, upper and lower intermolar distances, upper and lower intercanine distances, Little's irregularity index and the incisor mandibular plane angle. An intraclass correlation test was performed and a correlation index>0.08 was accepted. After verifying the normal sample distribution (Shapiro-Wilks), a parametric test was used (t test), with a significance level set at 5%. RESULTS There was a decrease in the values of overjet, overbite and Little's irregularity index, whereas there was an increase in the lower intercanine distance and IMPA values. All these variables are influenced, at different levels, by the forward inclination of the lower incisors, an action that can be expected due to the force applied by the device on the dentition. The other variables did not show statistically significant differences. CONCLUSION After a mean time of 6.47 months of use of the mandibular advancement device, there were statistically significant changes in the dental positioning, but they were not clinically relevant. However, it is relevant that this device is commonly in use over long periods of time, making the monitoring of these patients of the utmost importance for the duration of their therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality of life of patients with obstructive sleep apnea syndrome treated with an intraoral mandibular repositioner.

BACKGROUND Obstructive sleep apnea syndrome (OSAS) is a very important and prevalent disease, which is associated with a poor quality of life in many patients. Treatments for OSAS include surgery, Continuous Positive Air way Pressure, and an intraoral mandibular repositioner (IOMR), but the tendency of sleep centers is to emphasize the apnea index, neglecting quality of life as treatment outcom...

متن کامل

Increase in upper airway volume in patients with obstructive sleep apnea using a mandibular advancement device

Introduction: Diagnosis, treatment and monitoring of patients with obstructive sleep apnea syndrome (OSAS) are crucial because this disorder can cause systemic changes. The effectiveness of OSAS treatment with intraoral devices has been demonstrated through cephalometric studies. Objective: The purpose of this study was to evaluate the effect of a mandibular advancement device (Twin Block, TB) ...

متن کامل

Alternatives to CPAP in the treatment of the obstructive sleep apnea syndrome.

The obstructive sleep apnoea syndrome (OSAS) results in excessive daytime sleepiness, impaired quality of life, and is associated with an increased risk of traffic accidents and cardiovascular disease. Nasal continuous positive airway pressure (CPAP), the standard treatment for OSAS provides immediate relief of symptoms and has only minor side effects. Nevertheless, an alternative treatment is ...

متن کامل

Research Paper: Oral rehabilitation after radiotherapy; a review on prosthetic treatment options

Head and neck radiotherapy has some intraoral side effects that affect the treatment planning for oral rehabilitation .some treatment options have been discussed in articles. Choosing the best treatment should be based on the patient’s oral conditions affected by radiotherapy.  

متن کامل

Non-CPAP therapies in obstructive sleep apnoea.

In view of the high prevalence and the relevant impairment of patients with obstructive sleep apnoea syndrome (OSAS) lots of methods are offered which promise definitive cures for or relevant improvement of OSAS. This report summarises the efficacy of alternative treatment options in OSAS. An interdisciplinary European Respiratory Society task force evaluated the scientific literature according...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of otorhinolaryngology

دوره   شماره 

صفحات  -

تاریخ انتشار 2017