Predictors of restenosis after implantation of 2.5 mm stents in small coronary arteries.
نویسندگان
چکیده
BACKGROUND The results of stent implantation for small coronary disease have been inconclusive. The purpose of the present study was to evaluate the factors in predicting the risk of angiographic restenosis after 2.5-mm stent implantation for small coronary arteries. METHODS AND RESULTS The study group comprised 134 consecutive patients who had a reference small coronary artery with diameter from 1.8 mm to 2.5 mm on quantitative coronary angiography and who had been successfully treated by stent implantation with a 2.5-mm stent. Of the 134 patients, 55 had angiographic restenosis (41%). The rate of target lesion revascularization was 32%. Diabetes mellitus, acute coronary syndrome, lesion length, bifurcation lesion, lower left ventricular ejection fraction (LVEF), stent strut, stent/artery ratio, and stent length were identified as predictors of restenosis by univariate analysis. Subsequent multivariate analysis revealed that lower LVEF (odds ratio (OR) 3.37, p=0.01), bifurcation lesion (OR 2.47, p=0.04), thicker stent strut (OR 2.30, p=0.04), and longer stent length (OR 1.05, p=0.02) were significant predictors of restenosis. CONCLUSIONS Two pre-interventional factors (reduced left ventricular function and bifurcated lesion) and 2 procedure-related factors (thickness of stent strut and total stent length) were identified as predictors of restenosis. These factors should be taken into account when deciding on the percutaneous coronary intervention strategy for small coronary artery disease.
منابع مشابه
Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملIncidence, Predictors, Treatment, and Long-Term Prognosis of Patients with Restenosis after Long Drug-Eluting Stent Implantation for Coronary Arteries
Background: Few data on the clinical course and management of patients experiencing restenosis after implantation of long drug-eluting stents treatment for coronary arteries was available. Objectives: The aim of this study was to evaluate the incidence, predictors, and long-term outcomes of patients with in-stent restenosis (ISR) after percutaneous coronary intervention (PCI) with long (33 mm &...
متن کاملPrevention of carotid artery restenosis after sirolimus-coated stent implantation in pigs.
BACKGROUND AND PURPOSE To test the feasibility of self-expanding drug-coated nitinol stents for prevention of restenosis in an animal model. Stent implantation in the carotid artery (CA) has been shown to be feasible for treatment of CA stenosis. Even though the restenosis rate in CA is reported to be lower than in the coronary and peripheral arteries, problems may arise with increasing numbers...
متن کاملSirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS).
BACKGROUND Sirolimus-eluting stents have been developed to prevent restenosis in the treatment of coronary artery disease. We investigated the risk of restenosis with use of sirolimus-eluting stents compared with bare-metal stents to assess possible differences. METHODS We enrolled 352 patients in whom one coronary artery required treatment, with diameter 2.5-3.0 mm and lesion length 15-32 mm...
متن کاملRestenosis is not associated with stent length in a pig model of coronary stent implantation.
BACKGROUND The aim of this study was to determine if stent length is by itself a risk factor for intimal proliferation and restenosis. Long lesions represent an independent risk factor for restenosis after coronary stent implantation. A longer stented segment might result in a higher probability of restenosis. METHODS Twenty-two 7-month-old male farm pigs underwent implantation of two steel s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 68 3 شماره
صفحات -
تاریخ انتشار 2004