Microwave open-ended coaxial dielectric probe: interpretation of the sensing volume re-visited

نویسندگان

  • Paul M Meaney
  • Andrew P Gregory
  • Neil R Epstein
  • Keith D Paulsen
چکیده

BACKGROUND Tissue dielectric properties are specific to physiological changes and consequently have been pursued as imaging biomarkers of cancer and other pathological disorders. However, a recent study (Phys Med Biol 52:2637-2656, 2007; Phys Med Biol 52:6093-6115, 2007), which utilized open-ended dielectric probing techniques and a previously established sensing volume, reported that the dielectric property contrast may only be 10% or less between breast cancer and normal fibroglandular tissue whereas earlier data suggested ratios of 4:1 and higher may exist. Questions about the sensing volume of this probe relative to the amount of tissue interrogated raise the distinct possibility that the conclusions drawn from that study may have been over interpreted. METHODS We performed open-ended dielectric probe measurements in two-layer compositions consisting of a background liquid and a planar piece of Teflon that was translated to predetermined distances away from the probe tip to assess the degree to which the probe produced property estimates representative of the compositional averages of the dielectric properties of the two materials resident within a small sensing volume around the tip of the probe. RESULTS When Teflon was in contact with the probe, the measured properties were essentially those of pure Teflon whereas the properties were nearly identical to those of the intervening liquid when the Teflon was located more than 2 mm from the probe tip. However, when the Teflon was moved closer to the probe tip, the dielectric property measurements were not linearly related to the compositional fraction of the two materials, but reflected nearly 50% of those of the intervening liquid at separation distances as small as 0.2 mm, and approximately 90% of the liquid when the Teflon was located 0.5 mm from the probe tip. CONCLUSION These results suggest that the measurement methods reported in the most recent breast tissue dielectric property study are not likely to return the compositional averages of the breast tissue specimens evaluated, and thus, the conclusions reached about the expected dielectric property contrast in breast cancer from this specimen study may not be correct.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust low cost open - ended coaxial probe for dielectric spectros - copy in laboratory and in - situ applications

High-frequency electromagnetic (HF-EM) measurement techniques, e.g. dielectric spectroscopy, give inside into soil physical properties which are related to soil/water interactions such as the soil water characteristics. The open-ended coaxial line technique offers a non destructive determination of dielectric spectra of fine grained soil. In this study, a commercially available Agilent high tem...

متن کامل

Non-invasive and continuous monitoring of the sol-gel phase transition of supramolecular gels using a fast (open-ended coaxial) microwave sensor.

An open coaxial re-entrant microwave sensor has been used for the non-invasive and continuous monitoring of the sol-gel transition of physical gels characterized by different gelation mechanisms, solvents, compositions, and stabilities. Comparison of measurements by differential scanning calorimetry allowed the identification of the phase transition by a change in the dielectric properties of t...

متن کامل

Study of Dielectric Properties of Biological Tissues in the Microwave Frequency Range

The complex dielectric constants at room temperature of various goat tissues (liver, muscle, kidney, heart and brain) and corn syrup were measured in the frequency range 1 to 10 GHz with the help of a HP Network Analyzer N5230A. Open ended coaxial cable method was employed for the measurement. The system imperfections are completely avoided by calibrating the system with four known materials an...

متن کامل

Some calculation methods and universal diagrams for measurement of dielectric constants using open-e - Microwaves, Antennas and Propagation, IEE Proceedings H

Several formulas for the calculation of the admittance of open-ended coaxial probes from the complex permittivity, E, of the measured medium and the dimensions of the probe are presented. The inverse problem, calculation of c from the measured admittance of the probe, is also studied in detail. These formulas are discussed and compared in terms of numerical calculations. New universal diagrams ...

متن کامل

Dielectric Properties of Biomass/Biochar Mixtures at Microwave Frequencies

Material dielectric properties are important for understanding their response to microwaves. Carbonaceous materials are considered good microwave absorbers and can be mixed with dry biomasses, which are otherwise low-loss materials, to improve the heating efficiency of biomass feedstocks. In this study, dielectric properties of pulverized biomass and biochar mixtures are presented from 0.5 GHz ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014