Study and Optimization of Performance Parameters of Air- Conditioner by Using Waste Water of Water-Cooler
نویسندگان
چکیده
Reduction of energy consumption and rise of cooling is a major concern in the air conditioning system especially in the area with very hot weather conditions. In hot weather conditions, the air conditioner takes more electrical power consumption to bring the comfort in specified area. In many Middle East countries, the atmospheric temperature approaches 40°C to 50°C or sometimes higher. During these temperature conditions, the air conditioner compressor continuously works and consumes more electrical power. On the other hand, the waste water of water cooler is drained out freely in atmosphere. This waste water generally leaves at its minimum to maximum temperature which is shear wastage of energy. These two areas are identified where the compressor is working continuously due to more temperature of condenser environment. To extract the energy from the wastage, a combination of air conditioner and water cooler is purposed in the present investigation. The waste water of water cooler can be sprayed on the condenser of air conditioner so that efficiency of air conditioner can be increased. To investigate the effect, Drip Rate, Drip Position and Fan Speed were taken as process parameters whereas Amperage, Sucking Temperature and Humidity were taken as response parameters. In this experiment, L9 orthogonal array was used. Results show that the effect of running amperage is found to affect the performance significantly & its low value for optimum performance is recommended. KeywordsHumidity, power consumption, running amperage, sucking temperature, window-air-conditioner.
منابع مشابه
Waste water ammonia stripping intensification using microfluidic system
This paper reports the results of experimentally removing ammonia from synthetically prepared ammonia solution using a micro scale mixing loop air stripper. Effects of various operational parameters (such as: pH, air flow rate, wastewater flow rate and initial ammonia concentration) were evaluated. By increasing the pH from 10 to 12.25 the amount of KLa increased from 0.26 to 0.73 hr-1. A consi...
متن کاملTesting of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)
This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...
متن کاملDesign and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملSynthesis of activated carbon/zinc oxide nanocomposite from rapeseed plant waste by green chemistry method, evaluation of its performance in Methylene Blue pigment removal and optimization of influencing parameters using design expert
Background and Objective: Due to the water shortages and the presence of industrial pollutants in water resources, wastewater treatment, especially colored wastewater, is essential. The aim of this study was to treat wastewater containing Methylene Blue dye using activated carbon nanocomposite/zinc oxide nanoparticles (ZnO/AC) obtained from canola oil waste by green method. Materials and Metho...
متن کاملDevelopment of a Pilot Plant Solar Liquid Desiccant Air Conditioner for the Northern Region of Iran
In a 10-ton capacity pilot plant solar liquid desiccant air conditioner (LDAC) developed, dehumidification of the outside air is achieved through a honeycomb packed-bed heat and mass exchanger, using lithium chloride solution as the desiccant. The dry air obtained from the dehumidification process is evaporative cooled inside a cooling pad and directed into the conditioned space. The dilute sol...
متن کامل