Soft tissues surrounding vascular injuries are known to vibrate at audible and palpable frequencies, producing bruits and thrills. We report the results of a feasibility study where Doppler ultrasound (US) was used to quantitatively estimate the tissue vibrations after induced trauma in an animal model. A software-programmable US system was used to acquire quadrature-demodulated ensembles of received US echoes bypassing clutter filtering and other conventional Doppler processing stages. The waveforms of tissue velocity surrounding the injury site were then estimated from the clutter data using autocorrelation and analyzed to determine vibration characteristics. Six New Zealand white rabbits and two juvenile pigs were used for the study. The femoral artery of the anesthetized animal was punctured with an 18-gauge needle to model a peripheral arterial trauma, and the liver was surgically exposed and incised to model organ trauma. Two types of oscillatory tissue motion were observed: "vibrations" with high frequency (>50 Hz) and low peak-peak amplitude (<1 microm) and "flutter" with low frequency (<50 Hz) and high peak-peak amplitude (>1 microm). Active bleeding in femoral artery punctures produced tissue vibrations at the frequency of 323 +/- 214 Hz (mean +/- standard deviation, pooled for both rabbits and pigs) and the amplitude of 0.24 +/- 0.15 microm. Active bleeding in liver incisions produced vibrations at the frequency of 120 +/- 47 Hz and the amplitude of 0.33 +/- 0.25 microm. Flutter was observed in punctured arteries at the frequency of 28 +/- 13 Hz the amplitude of 2.92 +/- 1.75 microm, and in incised livers at the frequency of 26 +/- 6 Hz and the amplitude of 1.53 +/- 0.76 microm. In a punctured artery, the vibration frequency and phase of tissue surrounding the artery were highly correlated between neighboring locations in tissue (correlation coefficient = 0.98), and with the flow oscillations in the lumen (correlation coefficient = 0.96). This preliminary study indicates that tissue vibrations could provide additional physiologic information for detecting, localizing and monitoring internal bleeding using US.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcutaneous Localization of Arterial Bleeding by Two-Dimensional Ultrasonic Imaging of Tissue Vibrations

Arterial bleeding into a free space is known to cause local vibrations in tissue. To study the effectiveness of utilizing these tissue vibrations in localizing the site of arterial bleeding, we have developed an algorithm for ultrasonically imaging these tissue vibrations. Simulation results indicate that our algorithm can correctly detect vibrations in the presence of pulsatile wall motion, bl...

متن کامل

Comparative study of ultrasonic vibrations assisted EDM and magnetic field assisted EDM processes

In this investigation, the material removal rate, tool wear rate and surface integrity obtained by EDM, ultrasonic vibrations assisted EDM and magnetic field assisted EDM were studied and compared with together to show the quality of the effects of applying each of ultrasonic vibrations to tool and magnetic field around gap distance of EDM process on material removal rate, tool wear rate, and s...

متن کامل

Investigating the Ultrasonic Assistance in the Tube Hydroforming Process

The purpose of introducing ultrasonic vibrations in the tube hydroforming process is to create more formability by obtaining a lower corner radius, improve thickness distribution of the wall and provide good tribological conditions at the tube and the die interface. Vibrations imposed on the die create alternating gaps which improve the formability in the tube hydroforming process in the presen...

متن کامل

Tissue Engineering Scaffolds: History, Types and Construction Methods

Tissue engineering is a rapidly growing research field, potentially capable of de novo tissue and organ construction. This approach is used to improve efficiency both in the tissue and cell culture. This method is required to provide bodies in vivo three-dimensional conditions outside of the body (ex vivo). To achieve this goal, given tissue cells are cultured on the tissue engineering scaffold...

متن کامل

Numerical and analytical investigation of an ultrasonic assisted ECAP process

One of the great challenges in the processing of materials using Equal Channel Angular Pressing (ECAP) is the high forming forces required to produce large shear deformation in the material. Researchers show that the friction forces between the die and the sample constitute a great part of the total forming forces. Recently, ultrasonic vibrations are successfully implemented into the ECAP proce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 32 8  شماره 

صفحات  -

تاریخ انتشار 2006