The feasibility and safety of a through-and-through wire technique for central venous occlusion in dialysis patients

نویسندگان

  • Yonghui Huang
  • Bing Chen
  • Guosheng Tan
  • Gang Cheng
  • Yi Zhang
  • Jiaping Li
  • Jianyong Yang
چکیده

BACKGROUND To retrospectively compare the operation time, success rate and efficacy between unidirectional and bidirectional procedures in the treatment of central venous occlusion diseases (CVOD), assess the advantages of the bidirectional approach, and determine the characteristics of CVOD appropriate for the bidirectional approach treatment. METHODS A total of 49 patients who underwent endovascular interventions with all relevant data between January 2011 and December 2015 at the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China, were included in this retrospective study, and were categorized into two groups: the 19 patients in group 1 had undergone percutaneous transluminal venoplasty (PTV) via a conventional technique (unidirectional procedure from the vein distal or proximal to the obstructive lesion), and the 30 in group 2 had undergone flossing wire technique (bidirectional procedure from femoral vein and the vein distal to obstructive lesion and using a flossing wire technique). The technical success rate, the fluoroscopy time in the procedure, perioperative complications, and patency were evaluated retrospectively. RESULTS Compared with group 1, group 2 had a higher initial technical success rate (83.33% vs. 47.36%, p = 0.012) but a shorter fluoroscopy time (82.6 ± 26.1 vs. 116.1 ± 42.1, p = 0.048). Receiver operating characteristic (ROC) analysis indicated that a lesion with a length of 6.5 cm was the best predictor of technique success (p = 0.02) in group 1, but no cut-off value was identified for group 2. There were no significant differences in perioperative complications between these two groups. The complication rates were 31.58% (6/19) in group 1 and 6.67% (2/30) in group 2, (p = 0.043), respectively. No significant difference was observed between these two groups with respect to the stent patency rate. CONCLUSION Compared with the conventional technique, the flossing wire technique has a higher success rate, shorter fluoroscopy time, fewer complications and similar patency rate. It is a feasible treatment for CVOD, especially for long obstructive lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

حل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال

Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...

متن کامل

Skin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections

Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...

متن کامل

Effectiveness of Permanent Implantable Catheter (Polysite) in Children with Cancer

Abstract Background Totally implantable central venous access devices (ports) have been available for over 10 years, but have not been achieved widespread use in pediatric oncology patients. Ports facilitate the administration of chemotherapy in children with cancer. Materials and Methods In this study, early complications of implantable central venous access devices in children with diff...

متن کامل

Fibrin sheath removal from central venous catheters: an internal snare manoeuvre.

BACKGROUND Dysfunction of haemodialysis catheters is most commonly due to a narrowing of the catheter lumen and/or formation of a fibrin sheath around the catheter tip. Reported methods for restoring patency of the catheter lumen include passage of a J-tipped guide wire, passage of a biopsy brush through the catheter, or infusion of a thrombolytic agent into the catheter. While these methods ar...

متن کامل

Correlation between Religious Beliefs and Quality of Life in Dialysis Patients Referred to Shahid Rahnemoon Hospital, Yazd-2012

Introduction: The most important consequence of nephrogenic disease is the chronic renal failure and unfortunately, there is no significant program to improve the life quality of these patients. Although they need mental support as well as physical rehabilitation but all current endeavors focused on increasing their physical ability not the mental aspect. The aim of this study was to evaluat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016