Multi-purpose ECG telemetry system
نویسندگان
چکیده
BACKGROUND The Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices. METHODS In this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device's mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject's chest, customized ECG signal processing and interpretation pipeline is presented for each working mode. RESULTS We present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal's abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results of both short-term post-event recorder and 12-leads golden standard ECG recorder. CONCLUSIONS The proposed multi-purpose ECG device allows physicians to choose the working mode of the same device according to the patient status. The proposed device was designed to allow patients to manage the technical requirements of both working modes. Post-event short-term ECG recording using the proposed design provide physicians reliable three ECG leads with direct symptom-rhythm correlation.
منابع مشابه
Clinical usefulness of the EASI 12-lead continuous electrocardiographic monitoring system.
To purchase electronic or print reprints, contact The InnoVision Group, 101 Columbia, Aliso Viejo, CA 92656. Phone, (800) 809-2273 or (949) 362-2050 (ext 532); fax, (949) 362-2049; e-mail, [email protected]. of the heart, but rather to derive continuous monitoring information from the 1 or 2 most commonly used ECG leads. Recent research and national guidelines on monitoring for myocardial ische...
متن کاملComparison of non-invasive and implanted telemetric measurement of blood pressure and electrocardiogram in conscious beagle dogs.
INTRODUCTION The objective of this study was to evaluate the ability of a non-invasive telemetry monitoring system to detect and quantify changes in blood pressure and electrocardiogram (ECG) parameters in response to vehicle, L-NAME or minoxidil administration to freely moving beagle dogs. Data from a non-invasive telemetry monitoring system were compared to data captured from an invasive tele...
متن کاملDifferences in Alarm Events between Disposable And
Background Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. Objective To examine differences in alarm events between disposable and reusable ECG-LWs. Method Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, asse...
متن کاملMeasurement of Blood Flow Velocity Waveforms in the Carotid, Brachial and Femoral Arteries during Head-Up Tilt
The purpose of this study is to measure blood velocities in carotid, brachial and femoral arteries with synchronized measurement of electrocardiogram (ECG) during head-up tilt (HUT) using a developed telemetry measurement system. The velocity waveforms and ECG are continuously measured in six putatively healthy young subjects for 130 s during supine and 90 degrees HUT. From the measured peak sy...
متن کاملDifferences in alarm events between disposable and reusable electrocardiography lead wires.
BACKGROUND Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. OBJECTIVE To examine differences in alarm events between disposable and reusable ECG-LWs. METHOD Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, ...
متن کامل