The possibility of increasing the apertures of the LCLS gas attenuator/gas detector system is considered. It is shown that increase of the apertures from 3 to 6 mm, together with 4fold reduction of the operation pressure does not adversely affect the vacuum conditions upstream or downstream. No change of the pump speed and the lengths of the differential pumping cells is required. One minor modification is the use of 1.5 cm long tubular apertures in the end cells of the differential pumping system. Reduction of the pressure does not affect performance of the gas attenuator/gas detector system at the FEL energies below, roughly, 2 keV. Some minor performance degradation occurs at higher energies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Physics Analysis of a Gas Attenuator with Argon as a Working Gas

A gas attenuator is an important element of the LCLS facility. The attenuator must operate in a broad range of x-ray energies, provide attenuation coefficient between 1 and 10 with the accuracy of 1% and, at the same time, be reliable and allow for many months of un-interrupted operation. S. Shen [1] has recently carried out a detailed design study of the attenuator based on the use of nitrogen...

متن کامل

Possibility of using plasma-processed hybrid nanofibers to remove toluene in air stream

Introduction: Despite nanofibers have attracted great interests for filtering particulate matters from the air stream, fewer studies have been done on the feasibility of their use in the removal of gas pollutants, while the both pollutants are present in the most workplaces. Toluene is a toxic and mutagenic substance, and chronic exposure to its low levels can lead to a wide range of adverse he...

متن کامل

X-ray attenuation cell

To minimize the pulse-to-pulse variation, the LCLS FEL must operate at saturation, i.e. 10 orders of magnitude brighter spectral brilliance than 3-generation light sources. At this intensity, ultra-high vacuums and windowless transport are required. Many of the experiments, however, will need to be conducted at a much lower intensity thereby requiring a reliable means to reduce the x-ray intens...

متن کامل

Effect of Bed Diameter on the Hydrodynamics of Gas-Solid Fluidized Beds

Effect of scale on the hydrodynamics of gas-solid fluidized beds was investigated in two fluidized beds of 152 mm and 78 mm in diameter.  Air at room temperature was used as the fluidizing gas in the bed of sand particles. The Radioactive Particle Tracking (RPT) technique was employed to obtain the instantaneous positions of the particles at every 20 ms of the experiments. These data were u...

متن کامل

Investigation of Different Validation Parameters of Micro Gas Turbine for Range Extender Electric Truck

Nowadays the demand for reducing pollutant emissions and fuel consumption have paved the way of developing more fuel-efficient power generation system for transportation sector. Micro gas turbine (MGT) system can be an alternative to internal combustion reciprocating engine due to its light-weight and less fuel consumption. In this paper, some major running and operating characteristics of MGT ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008