Energy Dispersive Spectroscopy (EDS) has been used for many years to analyse the chemical composition of materials, including biological matter. However, the physical limitations of often being able to use only low beam currents, low accelerating voltages and only generating very low X-Ray count rates on a sample mainly comprised of light elements meant that until now, biological EDS has been somewhat limited in its practical application.
منابع مشابه
Investigation of Multiple, Large Area EDS Detectors on an SEM Capable of Various Mounting Geometries for Optimal EDS Analysis
It is common knowledge that collecting EDS data with dual large area SDD detectors from 180 degree opposing geometries has proven extremely beneficial with highly topographic samples [REF 1]. Traditionally, using high kV, the high count rates achievable from today’s SDD EDS detectors have been used to significantly reduce the time needed to acquire the statistical data necessary for X-ray analy...
متن کاملElemental Analysis of Biological and Cryogenic Samples
Introduction Commercial production of large-area silicon drift detectors (SDDs) heralds an exciting new time in biological elemental analysis. Improved low-energy performance and higher collection efficiencies mean EDS is no longer limited by low count rates and poor solid angles. High count rates can be achieved on all types of materials, including soft biological tissues, without altering nor...
متن کاملInnovations in Eds and Ebsd Microanalysis: Hyperspectral Imaging for Planetological Applications Using Silicon Drift Detectors
Within the last decade, silicon drift detectors (SDD) systems have become more and more popular in the field of energy-dispersive spectroscopy (EDS). The main characteristic of the SDDs is their extremely high pulse load capacity of up to 750,000 counts per second at good or reasonable energy resolution (<123 eV Mn-Kα, <46 eV C-Kα at 100,000 cps). These properties in conjunction with electron b...
متن کاملTrace Element Analysis in Geochemical Systems by STEM/EDS
Until recently, measurement of trace elements with ppm concentrations has been inaccessible to STEM EDS. Development of fast SDD detectors with solid angles > 1/2 steradian and faster processors are now making such measurements a reality. STEM EDS measurements already have a low brehmsstrahlung background owing to thin samples. However, the combination of high beam currents required to attain s...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کامل