Accurate and Easy Measurement of Sliding Distance of Intramedullary Nail in Trochanteric Fracture
نویسندگان
چکیده
BACKGROUND In daily clinical practice, it is essential to properly evaluate the postoperative sliding distance of various femoral head fixation devices (HFD) for trochanteric fractures. Although it is necessary to develop an accurate and reproducible method that is unaffected by inconsistent postoperative limb position on radiography, few studies have examined which method is optimal. Therefore, the purpose of this study is to prospectively compare the accuracy and reproducibility of our four original methods in the measurement of sliding distance of the HFD. METHODS Radiographs of plastic simulated bone implanted with Japanese proximal femoral nail antirotation were taken in five limb postures: neutral, flexion, minute internal rotation, greater external rotation, and flexion with external rotation. Orthopedic surgeons performed five measurements of the sliding distance of the HFD in each of the flowing four methods: nail axis reference (NAR), modified NAR, inner edge reference, and nail tip reference. We also assessed two clinical cases by using these methods and evaluated the intraclass correlation coefficients. RESULTS The measured values were consistent in the NAR method regardless of limb posture, with an even smaller error when using the modified NAR method. The standard deviation (SD) was high in the nail tip reference method and extremely low in the modified NAR method. In the two clinical cases, the SD was the lowest in the modified NAR method, similar to the results using plastic simulated bone. The intraclass correlation coefficients showed the highest value in the modified NAR method. CONCLUSIONS We conclude that the modified NAR method should be the most recommended based on its accuracy, reproducibility, and usefulness.
منابع مشابه
Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures – postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate
BACKGROUND In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the r...
متن کاملGamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults.
BACKGROUND Two types of implants used for the surgical fixation of extracapsular hip fractures are cephalocondylic intramedullary nails, which are inserted into the femoral canal proximally to distally across the fracture, and extramedullary implants (e.g. the sliding hip screw). OBJECTIVES To compare cephalocondylic intramedullary nails with extramedullary implants for extracapsular hip frac...
متن کاملElastic Stable Intramedullary Nailing of Femoral Shaft Fracture-Experience in 48 Children
Background: Femoral shaft fractures are an incapacitating pediatric injury accounting for 1.6% of all pediatric bonyinjuries. Management of these fractures is largely directed by age, fracture pattern, associated injuries, built of the childand socioeconomic status of the family. We retrospectively evaluated the use of elastic stable intramedullary nail (ESIN)in surgical management of femoral s...
متن کاملDetermination of the Best Method of Tibial Nail Length Estimation in Patients with Tibia Fracture
Background & Aims: Tibia fractures are the most common long bone fracture. Due to minimal soft tissue and its blood supply, inadequate treatment of injuries could be a major cause of morbidity and disability. The intramedullary nail is the preferred method of treatment; however, despite all previous studies, no accurate method to measure nail length prior to surgery exists as yet. Due to the im...
متن کاملIntramedullary nails versus sliding hip screws for AO/OTA 31-A2 trochanteric fractures in adults: A meta-analysis.
OBJECTIVES The optimum treatment with intramedullary nails (IMN) or sliding hip screws (SHS) for type 31-A2 trochanteric fractures remains controversial. Therefore, we performed a meta-analysis of randomized controlled trials (RCTs) to compare IMN with SHS in AO/OTA 31-A2 trochanteric fractures. MATERIAL AND METHODS Databases including PubMed, Cochrane, and Embase were searched to identify RC...
متن کامل