Double-Low Dose Protocol of Computed Tomography Pulmonary Angiography (CTPA) in the Diagnosis of Pulmonary Embolism: A Feasible Approach for Reduction of Both Contrast Medium and Radiation Doses
نویسنده
چکیده
This article discusses a hot topic on double low-dose protocol of computed tomography pulmonary angiography (CTPA) in the diagnosis of pulmonary embolism, with a special focus on a recent paper published in the British Journal of Radiology about the feasibility of this technique. Three aspects will be discussed in this review: First, both kVp and contrast medium can be reduced without affecting image quality when compared to the standard CTPA protocol; second, a low-pitch protocol is comparable to the high-pitch spiral image acquisition with similar image quality achieved, but at lower radiation dose; and finally, the double low-dose CTPA protocol can achieve diagnostic images in patients with body mass index up to 35 kg/m2.
منابع مشابه
Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملIncidental Findings in Patients Evaluated for Pulmonary Embolism Using Computed Tomography Angiography
Introduction: Pulmonary embolism (PE) is a common lethal disease that its clinical symptoms may be seen in many other diseases. Computed tomography pulmonary angiography (CTPA) is a valuable diagnostic modality for detection of PE. In addition, it can accurately detect the other diseases with clinical symptoms similar to PE. The aim of this study is to evaluate the frequency of PE and nonemboli...
متن کاملSubmillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging
OBJECTIVES To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. MATERIALS AND METHODS Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different prot...
متن کاملDiagnostic yield of CT pulmonary angiography in the diagnosis of pulmonary embolism: A single center experience
Zhonghua Sun1* and Jing Lei2 1Department of Medical Radiation Sciences, Curtin University, Perth, Western Australia, 6845, Australia 2Department of Medical Imaging, First Affiliated Hospital of Kunming Medical University, Yunnan, 650032, China *Author for correspondence: Tel: +61892667509 Fax: +61892662377 E-mail: [email protected] Submitted: August 18, 2017 Accepted: September 13, 2017 Publi...
متن کاملEvaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography
Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...
متن کامل