Impact of Hemodialysis Catheter Dysfunction on Dialysis and Other Medical Services: An Observational Cohort Study

نویسندگان

  • Robert I. Griffiths
  • Britt B. Newsome
  • Grace Leung
  • Geoffrey A. Block
  • Robert J. Herbert
  • Mark D. Danese
چکیده

Practice guidelines define hemodialysis catheter dysfunction as blood flow rate (BFR) <300 mL/min. We conducted a study using data from DaVita and the United States Renal Data System to evaluate the impact of catheter dysfunction on dialysis and other medical services. Patients were included if they had ≥8 consecutive weeks of catheter dialysis between 8/2004 and 12/2006. Actual BFR <300 mL/min despite planned BFR ≥300 mL/min was used to define catheter dysfunction during each dialysis session. Among 9,707 patients, the average age was 62,53% were female, and 40% were black. The median duration of catheter dialysis was 190 days, and the cohort accounted for 1,075,701 catheter dialysis sessions. There were 70,361 sessions with catheter dysfunction, and 6,33 1 (65.2%) patients had at least one session with catheter dysfunction. In multivariate repeated measures analysis, catheter dysfunction was associated with increased odds of missing a dialysis session due to access problems (Odds ratio [OR] 2.50; P < 0.001), having an access-related procedure (OR 2.10; P < 0.001), and being hospitalized (OR 1.10; P = 0.001). Catheter dysfunction defined according to NKF vascular access guidelines results in disruptions of dialysis treatment and increased use of other medical services.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

Comparing the early function and complications between fluoroscopic guidance and blindly insertion of permanent hemodialysis catheter

Objective: Chronic kidney disease (CKD) is a complicated kidney defect causing permanent failure in renal function in progressive stages. Hemodialysis is the most accepted treatment to maintain body’s fluid/electrolyte homeostasis at the terminal stages of the disease. Permanent hemodialysis catheter (permicath) may be inserted blindly or by fluoroscopic guidance. This study aimed to compare th...

متن کامل

Characteristics of Dialysis Patients in Hemodialysis Centers in Isfahan

Background: Chronic kidney disease is a health problem in today’s world and hemodialysis is an alternative method for patients with chronic renal failure. Preparing provincial and national information on the situation of patients can play a significant role in improving the quality of services provided to patients undergoing hemodialysis. Objective: This ...

متن کامل

Comparison of infectious complications between incident hemodialysis and peritoneal dialysis patients.

The impact of dialysis modality on infection, especially early in the course of dialysis, has not been well studied. This study compared infection between hemodialysis (HD) and peritoneal dialysis (PD) from the start of dialysis and evaluated factors that have an impact on infection risk. In this observational cohort study, all incident dialysis patients (n = 181; HD 119 and PD 62) at a single ...

متن کامل

Patterns of Hemodialysis Catheter Dysfunction Defined According to National Kidney Foundation Guidelines As Blood Flow <300 mL/min

Blood flow rate (BFR) <300 mL/min commonly is used to define hemodialysis catheter dysfunction and the need for interventions to prevent complications. The objective of this study was to describe patterns of unplanned BFR <300 mL/min during catheter hemodialysis using data from DaVita dialysis facilities and the United States Renal Data System. Patients were included if they received at least e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012