Amylase and lipase detection in hemorrhaged animals treated with HBOC-201.

نویسندگان

  • Françoise Arnaud
  • Richard McCarron
  • Daniel Freilich
چکیده

HBOC-201 may alter lipase and amylase detection on chemistry analyzers using optical methods and affect pancreatic function after trauma. Amylase and lipase measurements were correlated against HBOC-201 to evaluate interference on samples spiked with 0-6g/dL HBOC-201. The detection threshold was 2.5g/dL or none when measured, respectively, on Vitros 250 or Advia 1650 instruments. Amylase and lipase from blood samples collected from 55% EBV hemorrhaged Yucatan min-pigs showed peaks around 24-48 hours. Amylase increase was not significant between treatments but lipase was higher in HBOC-201-treated animals. Animals particularly affected by the injury had elevated enzymes after hemorrhagic shock, without significant clinical consequences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A hemoglobin based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus Hetastarch (HEX) in an uncontrolled liver injury hemorrhagic shock swine model with delayed evacuation.

BACKGROUND As HBOC-201 improves outcome in animals with hemorrhagic shock (HS), we compared HBOC-201 and HEX (used by U.S. military special operations forces) in a swine model of delayed evacuation and uncontrolled HS. METHODS Twenty-four Yucatan pigs underwent a grade III liver injury and were resuscitated with HBOC-201, HEX, or no fluid (NON). Additional infusions were given for hypotension...

متن کامل

Dose response of sodium nitrite on vasoactivity associated with HBOC-201 in a swine model of controlled hemorrhage.

Sodium nitrite (NaNO(2)) was evaluated in a 55% EBV hemorrhage swine model to mitigate the increased blood pressure due to HBOC-201. Animals were resuscitated by three 10 ml/kg infusions of either HBOC-201 or Hextend with and without NaNO(2). All vital signs, coagulation and blood chemistry were measured for 2 hr. HBOC-201-vasoconstriction was attenuated only after the first 10.8 μmol/kg NaNO(2...

متن کامل

A hemoglobin-based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in a moderate severity hemorrhagic shock swine model with delayed evacuation.

OBJECTIVE To evaluate the efficacy of HBOC-201 for resuscitation of hemorrhagic shock in a swine model incorporating soft tissue injury and delayed evacuation. METHODS A muscle crush injury and 40% estimated blood volume controlled hemorrhage was completed in 24 Yucatan mini-pigs. Pigs were untreated or resuscitated with HBOC-201 or 6% hetastarch (HEX) at 20 min. Invasive hemodynamics and cli...

متن کامل

Hemoglobin-based Oxygen Carrier (HBOC-201) and Escalating Doses of Recombinant Factor VIla (rFVIIa) as a Novel Pre-hospital Resuscitation Fluid in a Swine Model of Severe Uncontrolled Hemorrhage

Exsanguinating hemorrhage and unavailability of blood are major problems in pre-hospital trauma care. We investigated if combining rFVIIa with HBOC-201 reduces blood loss and improves physiologic parameters compared to HBOC alone. Swine underwent liver injury and were resuscitated with HBOC-201 alone or HBOC+90, 180 or 360 J.lg/kg rFVIIa before hospital arrival at 240 min; animals survived to 7...

متن کامل

Hemoglobin-based oxygen carrier (HBOC-201) and escalating doses of recombinant factor VIIa (rFVIIa) as a novel pre-hospital resuscitation fluid in a swine model of severe uncontrolled hemorrhage.

Exsanguinating hemorrhage and unavailability of blood are major problems in pre-hospital trauma care. We investigated if combining rFVIIa with HBOC-201 reduces blood loss and improves physiologic parameters compared to HBOC alone. Swine underwent liver injury and were resuscitated with HBOC-201 alone or HBOC+90, 180 or 360 μg/kg rFVIIa before hospital arrival at 240 min; animals survived to 72 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Artificial cells, blood substitutes, and immobilization biotechnology

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 2011