Peak oxygen uptake in arm ergometry: effects of testing protocol.
نویسندگان
چکیده
The purpose of this investigation was to determine if a new proposed arm ergometer protocol was advantageous in eliciting higher peak oxygen uptake (peak VO2) when compared with two protocols currently referred to in the literature. Ten male subjects were tested on three different exercise protocols; a discontinuous test (DT), a continuous test (CT) and a new proposed jump-max test (JMT). The CT began at a work rate of 33 watts (W) (40 rpm) with the power output (PO) being increased 16 W every 3 minutes. The DT began without resistance on the ergometer flywheel (50 rpm) and the work rate was increased by 25 W every 3 minutes with a 1-minute rest between stages. The JMT began with a 3-minute pretest to determine a PO which elicited a HR of 120 +/- 5 beat min-1. After a 2-minute rest, subjects began exercise at the predetermined work rate (80 rpm) with the PO being increased 20 W each minute of the test. Oxygen uptake was measured minute by minute via open circuit spirometry. Peak VO2 was higher (p less than 0.05) in the JMT (mean +/- SEM = 2.36 +/- 0.06 l.min-1) when compared with either (means +/- SEM = 2.16 +/- 0.07 l.min-1) or the CT (means +/- SEM = 2.04 +/- 0.10 l.min-1). No difference (p greater than 0.05) existed in peak VO2 between the CT and the DT. These data suggest that the proposed JMT may result in a higher measured peak VO2 in subjects when compared with either DT or CT of moderate to long duration.
منابع مشابه
Arm-cranking exercise assisted by Functional Electrical Stimulation in C6 tetraplegia: a pilot study.
Tetraplegic volunteers undertook progressive exercise training, using novel systems for arm-cranking exercise assisted by Functional Electrical Stimulation (FES). The main aim was to determine potential training effects of FES-assisted arm-crank ergometry (FES-ACE) on upper limb strength and cardiopulmonary (fitness) in tetraplegia. Surface FES was applied to the biceps and triceps during exerc...
متن کاملA time-saving incremental cycle ergometer protocol to determine peak oxygen consumption.
Previously we have demonstrated that an accelerated arm ergometry testing protocol results in a higher peak oxygen consumption than continuous or discontinuous protocols reported in the literature (Brit. J. Sports Med. 20: 25-26, 1986). The purpose of this investigation was to determine if an accelerated protocol was superior to two commonly used protocols in cycle ergometry. Nine male subjects...
متن کاملPower output for wheelchair driving on a treadmill compared with arm crank ergometry.
OBJECTIVES The limiting factors with regard to power output available for wheelchair ambulation have not been identified. The aim of the present study was to correlate power output during wheelchair driving with (i) power output and oxygen uptake during arm crank ergometry and (ii) arm muscle strength. METHODS Eleven disabled men were examined for maximal power output (POmax) during wheelchai...
متن کاملRating of Perceived Exertion as an Indicator of Exercise Intensity in Paraplegics
Background: Energy expenditure is of paramount importance in the assessment of usefulness of wheelchair for paraplegics. Despite widespread recognition of problems associated with currently available mobility systems for persons with spinal cord injuries, development of more efficient systems has been slow. Lack of a suitable and simple technique for the assessment of energy expenditure in par...
متن کاملMethods and protocols for incremental exercise testing in tetraplegia, using arm-crank ergometry assisted by Functional Electrical Stimulation
Cervical spinal cord injury (SCI) leads to tetraplegia, with paralysis and loss of sensation in the upper and lower limbs. The associated sedentary lifestyle results in an increased risk of cardiovascular disease. To address this, we require the design of exercise modalities aimed specifically at tetraplegia and methods to assess their efficacy. This paper describes methods for arm-crank ergome...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of sports medicine
دوره 20 1 شماره
صفحات -
تاریخ انتشار 1986