Folded Jamin interferometer: a stable instrument for refractive-index measurements.

نویسندگان

  • H Moosmüller
  • W P Arnott
چکیده

A novel two-beam interferometer for the measurement of a refractive index or its induced changes is described. This interferometer consists of only two optical elements and is largely insensitive to their movement. A laboratory prototype has been built. It uses a polarized version of the folded Jamin interferometer to allow for convenient phase adjustment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

Real-time detection of ambient aerosols using photothermal interferometry: Folded Jamin interferometer

Work in our laboratory has been directed at the development of a new class of instrumentation that can directly measure ambient aerosol absorption through photothermal interferometry. The hallmark of this approach is its ability to directly measure aerosol absorption without interference from aerosol scattering since the signal originates from the thermal dissipation of the spectrally absorbed ...

متن کامل

Cryogenic Refractive Index of Heraeus

This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.34—3.16 μm and temperature range of 120—335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASA’s Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Per...

متن کامل

-

In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...

متن کامل

“Study of stable gallium oxide heavey metal Ga2O3-Bi2O3-PbO system glasses proposed as a base for optically noble glazes and enamels”

Ultra optical glasses are proposed for attaining noble glazes of high reflection and shine. In addition, these glasses can be used as semi-mirrors and optical instruments. In this reseach attempts were devoted mainly to introduce a glass system with the highest possible refractive index in which the highest reflection is desirable. Thus different amounts of heavy metal oxides modifiers, such as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 1996