Comparison between adaptive and fixed stimulus paired-pulse transcranial magnetic stimulation (ppTMS) in normal subjects

نویسنده

  • H. W. Axelson
چکیده

Objectives: Paired-pulse TMS (ppTMS) examines cortical excitability but may require lengthy test procedures and fine tuning of stimulus parameters due to the inherent variability of the elicited motor evoked potentials (MEPs) and their tendency to exhibit a ‘ceiling/floor effects’ in inhibition trials. Aiming to overcome some of these limitations, we implemented an ‘adaptive’ ppTMS protocol and compared the obtained excitability indices with those from ‘conventional’ fixed-stimulus ppTMS. Methods: Shortand long interval intracortical inhibition (SICI and LICI) as well as intracortical facilitation (ICF) were examined in 20 healthy subjects by adaptive ppTMS and fixed-stimulus ppTMS. The test stimulus intensity was either adapted to produce 500 lV MEPs (by a maximum likelihood strategy in combination with parameter estimation by sequential testing) or fixed to 120% of resting motor threshold (rMT). The conditioning stimulus was 80% rMT for SICI and ICF and 120% MT for LICI in both tests. Results: There were significant (p < 0.05) intraindividual correlations between the two methods for all excitability measures. There was a clustering of SICI and LICI indices near maximal inhibition (‘ceiling effect’) in fixed-stimulus ppTMS which was not observed for adaptive SICI and LICI. Conclusions: Adaptive ppTMS excitability data correlates to those acquired from fixed-stimulus ppTMS. Significance: Adaptive ppTMS is easy to implement and may serve as a more sensitive method to detect changes in cortical inhibition than fixed stimulus ppTMS. Whether equally confident data are produced by less stimuli with our adaptive approach (as already confirmed for motor threshold estimation) remains to be explored. 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Id 152 – Paired Pulse Tms-emg and Tms-eeg in Epilepsy—a.a. De Goede a Id 178 – Longitudinal Simultaneous Dbs Fmri in the Rodent Id 186 – Repetition Suppression in Resting Motor Evoked Poten- Tials Evidenced by Increase in Intracortical Inhibition—

Objective: Epilepsy is characterized by an enduring predisposition to generate seizures, due to an increased cortical excitability (CE). Although the routine electroencephalogram (EEG) can assist in identifying increased CE, its sensitivity is low (30–55%). Therefore, we will investigate whether transcranial magnetic stimulation (TMS), another technique to measure CE, can be used to improve the...

متن کامل

Paired-pulse transcranial magnetic stimulation during preparation for simple and choice reaction time tasks.

Motor preparation for execution of both simple and choice reaction time tasks (SRT and CRT) involves enhancement of corticospinal excitability (CE). However, motor preparation also implies changes in inhibitory control that have thus far been much less studied. Short-interval intracortical inhibition (SICI) has been shown to decrease before CE increases. Therefore we reasoned that, if SICI cont...

متن کامل

Safety and tolerability of theta burst stimulation vs. single and paired pulse transcranial magnetic stimulation: a comparative study of 165 pediatric subjects

BACKGROUND Although single- and paired-pulse (sp/pp) transcranial magnetic stimulation (TMS) studies are considered minimal risk in adults and children, the safety profile for theta-burst TMS (TBS) is unknown. OBJECTIVE In this comparative analysis, we explored the rate, severity, and specific symptoms of TMS-related adverse effects (AEs) between sp/ppTMS and TBS in subjects between ages 6 an...

متن کامل

A new measure of cortical inhibition by mechanomyography and paired-pulse transcranial magnetic stimulation in unanesthetized rats.

Paired-pulse transcranial magnetic stimulation (ppTMS) is a safe and noninvasive tool for measuring cortical inhibition in humans, particularly in patients with disorders of cortical inhibition such as epilepsy. However, ppTMS protocols in rodent disease models, where mechanistic insight into the ppTMS physiology and into disease processes may be obtained, have been limited due to the requireme...

متن کامل

Human brain connectivity during single and paired pulse transcranial magnetic stimulation

OBJECTIVE Intracortical inhibition (SICI) and facilitation (ICF) in the human motor cortex can be measured using a paired pulse transcranial magnetic stimulation (ppTMS) protocol. Recently, a technical device has been introduced, which allows recording electroencephalographic (EEG) responses to TMS of a given scalp site. The latency, amplitude and scalp topography of such responses are consider...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017