Evaluation of insertion torque of different orthodontic miniscrews: An in vitro study

نویسنده

  • Hussein Ahmed
چکیده

*Department of P.O.P, college of dentistry, university of Mosul, Mosul, Iraq. Introduction Conservation of anchorage in totality has been a perennial problem to the traditional orthodontist. Conventional means of supporting anchorage have been used by either intra oral sites or relying on extra oral means. Both of these have their limitations. The extra oral forces very difficult device and some time the patient is not able to wear it. On the other hand, strict reliance on intra oral areas. Among the anchorage devices, micro screw implants have increasingly being used for orthodontic anchorage because of their absolute anchorage, easy placement and removal, and low cost. The small size of the miniscrew implants allows them to be placed into bone between the teeth, insertion is a less traumatic procedure, and they can be loaded soon after placement as there is no osseointegration around the screws but only fibrous integration. However, a notable complication is loosening of the screws even though they consist of a biocompatible titanium alloy. Drill screws are most commonly used for this purpose. A prerequisite for the insertion of screws is the preparation of a pilot hole with a minimum diameter equal to the screws core. Thermal necrosis of bone has also been observed. Another problem frequently encounters during the insertion of a screw after drilling is stripping of the bone threads when working in thin cortical bone. Drill-free screws or self-drilling screws are a recent development. They have a tip like a cork screw and specially formed cutting flute that enables them to be inserted without drilling. This results in less insertion time and more patient compliance. Drill-free screws can provide intensive screw bone contact and inserting them produces little bone debris and less thermal damage. Background and objective: The purpose of this study was to evaluate the torque insertion for drill and non drill techniques of two commercially available miniscrews. Methods: Eighty mini screws (forty Dentos miniscrews/Korea and forty 3M miniscrews/ USA), having the same length and diameter, were divided into two groups for each type. Two techniques, non-drill and drill, were used. In drill techniques, manufacturer recommended drill was used. Two bovine tibias were obtained. The first technique used pre drill hole, which was made in the bone using the recommended bur (1.0 diameter). The mini-screw was placed at 9 mm manually, then the remaining 1 mm was inserted through digital torque meter. The same procedure was repeated but without a pilot hole. Results: 3M miniscerws gave high torque insertion in two techniques. Conclusion: The shape, thread design and tip geometry of miniscerw play an important role in the torque insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews – an in vitro study

BACKGROUND The aim of the present study was to evaluate the relationship between insertion torque and stability of miniscrews in terms of resistance against dislocation, then comparing a self-tapping screw with a self-drilling one. METHODS Insertion torque was measured during placement of 30 self-drilling and 31 self-tapping stainless steel miniscrews (Leone SpA, Sesto Fiorentino, Italy) in s...

متن کامل

Torque Loss After Miniscrew Placement: An In-Vitro Study Followed by a Clinical Trial

To evaluate torque loss a week after insertion, both in an in vivo and an in vitro experimental setup were designed. In the in vivo setup a total of 29 miniscrews were placed in 20 patients who underwent orthodontic treatment. Maximum insertion torque (MIT) was evaluated at insertion time (T1). A week later, insertion torque was measured again by applying a quarter turn (T2); no load was applie...

متن کامل

Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length.

OBJECTIVE To determine the variation in the insertion torque of orthodontic miniscrews according to the screw length, diameter, and shape. MATERIALS AND METHODS The maximum insertion torque (MIT) was measured using a torque tester at a constant speed of 3 rotations per minute. Cylindrical and taper type of miniscrews (Biomaterials Korea Inc, Seoul, Korea) with different lengths, diameters, an...

متن کامل

Orthodontic miniscrews: an experimental campaign on primary stability and bone properties.

OBJECTIVE To evaluate the primary stability of different shaped miniscrews through the acquisition of data regarding maximum insertion torque, pullout force, and a radiodiagnosic evaluation of bone characteristics. MATERIALS AND METHODS Sixty fresh porcine bone samples were scanned by computed tomography (CT) and cone-beam computed tomography (CBCT). By means of a dedicated software, CT and C...

متن کامل

Factors Associated with the Success of Orthodontic Miniscrews

Background and aims. Nowadays miniscrews are widely used as skeletal anchorage in orthodontics. However, the success rate of miniscrews is less than that of osseointegrated implants. The aim of this retrospective study was to evaluate factors influencing the success rate of orthodontic miniscrews. Materials and methods. Data of 244 miniscrews in 122 patients (99 females and 23 males, with a mea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016