Evaluation of the performance of a novel system for continuous glucose monitoring.

نویسندگان

  • Eva Zschornack
  • Christina Schmid
  • Stefan Pleus
  • Manuela Link
  • Hans-Martin Klötzer
  • Karin Obermaier
  • Michael Schoemaker
  • Monika Strasser
  • Gerhard Frisch
  • Günther Schmelzeisen-Redeker
  • Cornelia Haug
  • Guido Freckmann
چکیده

BACKGROUND The performance of a continuous glucose monitoring (CGM) system in the early stage of development was assessed in an inpatient setting that simulates daily life conditions of people with diabetes. Performance was evaluated at low glycemic, euglycemic, and high glycemic ranges as well as during phases with rapid glucose excursions. METHODS Each of the 30 participants with type 1 diabetes (15 female, age 47 ± 12 years, hemoglobin A1c 7.7% ± 1.3%) wore two sensors of the prototype system in parallel for 7 days. Capillary blood samples were measured at least 16 times per day (at least 15 times per daytime and at least once per night). On two subsequent study days, glucose excursions were induced. For performance evaluation, the mean absolute relative difference (MARD) between CGM readings and paired capillary blood glucose readings and precision absolute relative difference (PARD), i.e., differences between paired CGM readings were calculated. RESULTS Overall aggregated MARD was 9.2% and overall aggregated PARD was 7.5%. During induced glucose excursions, MARD was 10.9% and PARD was 7.8%. Lowest MARD (8.5%) and lowest PARD (6.4%) were observed in the high glycemic range (euglycemic range, MARD 9.1% and PARD 7.4%; low glycemic range, MARD 12.3% and PARD 12.4%). CONCLUSIONS The performance of this prototype CGM system was, particularly in the hypoglycemic range and during phases with rapid glucose fluctuations, better than performance data reported for other commercially available systems. In addition, performance of this prototype sensor was noticeably constant over the whole study period. This prototype system is not yet approved, and performance of this CGM system needs to be further assessed in clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

Development, Implementation, Monitoring and Evaluation of Performance Improvement Components of Isfahan Medical School Departments

Introduction: Departments are the major sub-system of university and quality improvement of the universities rides on the quality improvement of the departments. The researchers developed, implemented, and evaluated the appropriate components based on the results of self-assessment and external evaluation of institutional accreditation. Methods: In a case study on 32 departments of Medical Sch...

متن کامل

A Novel Continuous KNN Prediction Algorithm to Improve Manufacturing Policies in a VMI Supply Chain

This paper examines and compares various manufacturing policies which manufacturer may adopt so as to improve the performance of a vendor managed inventory (VMI) partnership. The goal is to maximize the combined cumulative profit of supply chain while minimizing relevant inventory management costs. The supply chain is a two-level system with a single manufacturer and single retailer at each lev...

متن کامل

تأثیر مداخله آموزشی مبتنی بر الگوی مراقبت پیگیر بر خودپایشی قند خون بیماران دیابتی نوع 2

Background and Aim: Appropriate control of blood sugar delays the onset and progression of diabetes mellitus (DM) complications. Nurses have a decisive role in the education of self-care behaviors to diabetic patients, including self-monitoring of blood glucose. The current study aimed at assessing the effect of educational intervention based on continuous care model on self-monitoring of blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 2013