Sensitivity of LR115 detector in diffusion chamber to 222Rn in the presence of 220Rn.
نویسندگان
چکیده
Determination has been made of the sensitivity of LR115 type 2-track detectors (in units of m) to 222Rn, measured in the presence of 220Rn. Measurements have been made by means of a widely used diffusion chamber while Monte Carlo simulations have also been conducted. The experimentally derived sensitivities for 222Rn and 220Rn were found to be 0.470+/-0.022 and 0.486+/-0.042 m, respectively. For Monte Carlo simulations, the sensitivities to 222Rn gas were found to range from 0.618 x 10(-2) m (assuming that all 218Po progeny decay before deposition onto the internal walls of the diffusion chamber) to 0.405 x 10(-2) m (assuming that all 215Po progeny are deposited on the internal walls of the same containment vessel before decaying). The sensitivity to 220Rn gas of 0.465 x 10(-2) m found from Monte Carlo simulations agrees to within uncertainty with experimental findings. The experimentally derived sensitivity value for 222Rn indicates that 30% of the 218Po progeny decay before deposition onto the internal walls of the diffusion chamber.
منابع مشابه
222Rn IN THE PRESENCE OF 220Rn
The sensitivities (in m) of bare LR115 detectors and detectors in diffusion chambers to 222Rn and 220Rn chains are calculated by the Monte Carlo method. The partial sensitivities of bare detectors to the 222Rn chain are larger than those to the 220Rn chain, which is due to the higher energies of alpha particles in the 220Rn chain and the upper energy limit for detection for the LR115 detector. ...
متن کاملIndoor 222Rn and 220Rn variations: Evidence for Boyle’s law
Background: Radon and its daughter product are a major source of natural radiation exposure, the measurement of radon concentration in dwellings is assuming ever increasing importance. It is known from recent surveys in many countries that radon and its progeny contributes significantly to total inhalation dose and is well established that radon when inhaled in large quantity causes lu...
متن کاملEnvironmental thoron (220Rn) : A review
Ever since studies on uranium miners established the presence of a positive risk coefficient for the occurrence of lung cancer in miners exposed to elevated levels of 222Rn and its progeny, there was a great upsurge of interest in the measurement of 222Rn in the environment and considerable data is generated on the levels of 222Rn in the environment across the worlds and is periodically ...
متن کاملExperimental study of track density distribution on LR 115 detector and deposition fraction of 218 Po in diffusion chamber
The radial distribution of track density on a solid-state nuclear track detector inside a diffusion chamber is a function of the fraction f of Po decay before deposition. In the present work, procedures are proposed to determine f experimentally by determining the track density distribution on an LR115 detector in a diffusion chamber. First, a relatively tall diffusion chamber, with a height of...
متن کاملComparison of Radon (222Rn) and Thoron (220Rn) Gamma Dosimetry in the Environment Using the ORNL Mathematical Phantom
Background: The potential hazards of exposure to radiation from radon have been of great concern worldwide, as it is associated with an increased risk of lung cancer. Radon (222Rn) and its progeny are the main sources of radioactivity in the environment. The half-life of 222Rn (3.82 days) is long enough for it to diffuse into and build up in homes. 220Rn or thoron from the 232Th series, and 219...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
دوره 56 6 شماره
صفحات -
تاریخ انتشار 2002