MRI of the neck at 3 Tesla using the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) sequence compared with T2-weighted fast spin-echo sequence.

نویسندگان

  • Yoshimitsu Ohgiya
  • Jumpei Suyama
  • Noritaka Seino
  • Shu Takaya
  • Masaaki Kawahara
  • Makoto Saiki
  • Syouei Sai
  • Masanori Hirose
  • Takehiko Gokan
چکیده

PURPOSE To evaluate motion artifacts, tissue contrasts, and lesion detectability in the neck with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) technique. MATERIALS AND METHODS A total of 46 patients referred for MRI of the neck were included in a comparison of T2-weighted BLADE (T2W-BLADE) sequence and T2W fast spin-echo (T2W-FSE) sequence. All examinations were performed at 3T using the same parameters. Two observers evaluated unlabelled images for motion artifacts, the preferred image quality, and lesion detectability. Region of interest (ROI)-based quantitative measurements were performed to assess tissue contrasts. The frequency of occurrence of the different assessed artifacts and the lesion detectability was tested using McNemar's test. Tissue contrasts were compared using the Wilcoxon paired test. Reader agreement was assessed using kappa test. RESULTS T2W-BLADE showed less ghosting and pulsation artifacts than T2W-FSE (P < 0.01). T2W-BLADE images were rated as better than or equal to T2W-FSE images in majority cases (93.5%; kappa = 0.64). There was not significant difference in tissue contrasts between T2W-BLADE and T2W-FSE. A total of 32 lesions were present in 32 patients and equally well seen on T2W-BLADE and T2W-FSE. CONCLUSION T2W-BLADE can reduce motion artifacts and provide tissue contrasts and lesion detectability equivalent to T2W-FSE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3T MR imaging of postoperative recurrent middle ear cholesteatomas: value of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted MR imaging.

BACKGROUND AND PURPOSE MR diagnostic of postoperative recurrent cholesteatomas is difficult. Our purpose was to compare multishot fast spin-echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted MR imaging (DWI) with array spatial sensitivity encoding technique (ASSET) single-shot echo-planar DWI and late postgadolinium T1-weighted MR im...

متن کامل

Functional magnetic resonance imaging using PROPELLER-EPI.

Periodically rotated overlapping parallel lines with enhanced reconstruction-echo-planar imaging (PROPELLER-EPI) is a multishot technique that samples k-space by acquisition of narrow blades, which are subsequently rotated until the entire k-space is filled. It has the unique advantage that the center of k-space, and thus the area containing the majority of functional MRI signal changes, is sam...

متن کامل

BLADE for T1-weighted contrast with spectral fat suppression: two different approaches for head and neck imaging

INTRODUCTION: Up to now, Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) or BLADE imaging has been applied to reduce motion artifacts mainly in T2-weighted imaging. Using an inversion pulse at the beginning of the sequence results in T1-weighted contrast – this technique has been evaluated for T1-weighted imaging in the brain after application of contras...

متن کامل

BLADE in sagittal T2-weighted imaging of the cervical spine: reduction of artifacts and value for clinical application

INTRODUCTION: Up to now, Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) or BLADE imaging has been proposed either to reduce motion artifacts in uncooperative patients, in cardiac or abdominal imaging or to reduce geometric distortions in echo planar imaging. Sagittal T2-weighted images of the cervical spine are prone to several kinds of artifacts such a...

متن کامل

Correction of geometric distortion in Propeller echo planar imaging using a modified reversed gradient approach.

OBJECTIVE This study investigates the application of a modified reversed gradient algorithm to the Propeller-EPI imaging method (periodically rotated overlapping parallel lines with enhanced reconstruction based on echo-planar imaging readout) for corrections of geometric distortions due to the EPI readout. MATERIALS AND METHODS Propeller-EPI acquisition was executed with 360-degree rotationa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 2010