Micro-Flow Calibration Facility at NIST

نویسندگان

  • James W. Schmidt
  • John D. Wright
چکیده

The Fluid Metrology Group (FMG) at the National Institute of Standards and Technology (NIST) is developing a primary, dynamic gravimetric liquid flow standard for use in the range 100 nL/min to 1 mL/min (and eventually lower). An elevated reservoir of water with a pressure head of a few centimeters provides a flow to the meter under test and the discharged water from it flows to a micro-balance. The flow is collected in a beaker which is weighed at intervals while it fills. The time-rate-of-change of the buoyancy-corrected mass of the beaker’s contents gives the mass flow. The FMG’s implementation of the flow standard will allow accurate measurements of non-steady flows and heterogeneous flows (liquids with cells, proteins, and other soluble and non-soluble components). Evaporation of the water from the beaker is a significant effect and must be measured or controlled accurately. Intermittent liquid wetting or “patchy” wettability of the pipette by the water in the beaker is also a significant effect. At present we are exploring two techniques: 1) using an oil film to limit evaporation, and 2) using a porous glass element to control capillary forces and evaporation losses. We present an uncertainty analysis for the first iteration of the flow standard. A preliminary calibration of a commercial flow meter was within 3 % or better down to 2 L/min of the unofficial calibrations conducted by the Danish and Swiss National Metrology Institutes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hydrocarbon Liquid Flow Calibration Service

This document provides a description of a 2 liter hydrocarbon liquid flow calibration standard operated by the National Institute of Standards and Technology (NIST) Fluid Metrology Group to provide flowmeter calibrations for customers. This facility uses a passive piston prover technique where fluid is driven by pumps while the measuring piston is pushed by the fluid over a measured length duri...

متن کامل

NIST Colorimetric Calibration Facility for Displays − Part 2

Development of a calibration facility for spectroradiometric, colorimetric, and goniometric measurements of displays, display colorimeters, and spectroradiometers has been completed at the National Institute of Standards and Technology (NIST). An overview of the facility and results of the characterization measurements are presented. The results show that the facility is capable of measuring co...

متن کامل

Calibration of High Heat Flux Sensors at NIST

An ongoing program at the National Institute of Standards and Technology (NIST) is aimed at improving and standardizing heat-flux sensor calibration methods. The current calibration needs of U.S. science and industry exceed the current NIST capability of 40 kW/m2 irradiance. In achieving this goal, as well as meeting lower-level non-radiative heat flux calibration needs of science and industry,...

متن کامل

New Photometric Calibration Programs at the National Institute of Standards and Technology

The NIST candela is maintained via standard photometers which have shown long-term stability better than 0.1% per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at NIST. A high-illuminance calibration facility has been developed. Four temperatur...

متن کامل

New photometric calibration programmes at the National Institute of Standards and Technology

The National Institute of Standards and Technology (NIST) candela is maintained via standard photometers which have shown long-term stability of better than 0.1 % per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at the NIST. A high-illuminance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015