High tibial valgus osteotomy using the Tomofix plate--medium-term results in young patients.
نویسندگان
چکیده
Proximal tibial valgus osteotomy is one of the treatment options for painful medial compartment osteoarthrosis and varus deformity of the knee in a young patient. We report our experience with medial opening wedge tibial osteotomy using the Tomofix plate in 46 patients (50 knees). The mean age was 39.5 years (range 30-49). All were male. Mean duration of follow-up was 60 months (36-72 months). There were no non-unions of the osteotomy site and the medial open-wedge healed without any need for bone graft or bone substitutes. There was functional improvement, as seen from the Oxford and Knee Society scores. Preoperative average knee flexion was 110 degrees (range, 90 - 125 degrees) which remained unchanged. The mean preoperative tibio-femoral angle (mechanical) was 7 degrees varus (range, 5-10 degrees); the postoperative angle was 6 degrees valgus (range 5 degrees-8 degrees). One knee was revised to total knee replacement after two years and was considered a failure. The Tomofix plate provided immediate stability, satisfactory healing of the osteotomy site without the need for bone graft or bone substitutes, and good functional results in young patients with isolated medial compartment degenerative disease.
منابع مشابه
Fixation stability of opening- versus closing-wedge high tibial osteotomy: a randomised clinical trial using radiostereometry.
Valgus high tibial osteotomy for osteoarthritis of the medial compartment of the knee can be performed using medial opening- and lateral closing-wedge techniques. The latter have been thought to offer greater initial stability. We measured and compared the stability of opening- and closing-wedge osteotomies fixed by TomoFix plates using radiostereometry in a series of 42 patients in a prospecti...
متن کاملLimb alignment after open-wedge high tibial osteotomy and its effect on the clinical outcome.
The purpose of this study was to evaluate the accuracy of alignment after open-wedge high tibial osteotomy and its effect on the clinical outcome. A prospective case series of 56 consecutive patients underwent open-wedge high tibial osteotomy fixed with a TomoFix plate fixator (Synthes, West Chester, Pennsylvania). The correction angle was radiologically determined preoperatively and at 6 month...
متن کاملEarly full weight bearing is safe in open-wedge high tibial osteotomy
BACKGROUND AND PURPOSE In open-wedge, valgus osteotomy of the upper tibia, there are concerns regarding the initial stability and ability to retain the correction. Rehabilitation protocols vary depending on the osteotomy technique and the fixation method. Angle-stable implants offer superior initial stability. Early full weight bearing appears to be possible using these implants. In this prospe...
متن کاملA Randomised Clinical Trial Using Radiostereometry
J Bone Joint Surg [Br] 2009;91-B:1459-65. Received 18 March 2009; Accepted after revision 19 June 2009 Valgus high tibial osteotomy for osteoarthritis of the medial compartment of the knee can be performed using medial openingand lateral closing-wedge techniques. The latter have been thought to offer greater initial stability. We measured and compared the stability of openingand closing-wedge o...
متن کاملHigh Tibial Valgus Osteotomy and Functional Outcome
Background: This is a case series of 76 knees of 62 patients who underwent upper tibial valgus osteotomy for treatment of medial compartment osteoarthritis during a 20-year period and who were followed for a mean of 7.6 years. Methods: The patients were evaluated by validated outcome assessment systems of general health status short form (SF-36), the Western Ontario McMaster osteoarthritis inde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 75 3 شماره
صفحات -
تاریخ انتشار 2009