Debonding force and deformation of two multi-stranded lingual retainer wires bonded to incisor enamel: an in vitro study.

نویسندگان

  • M E Cooke
  • M Sherriff
چکیده

The aim of the study was to examine, in vitro, the effect of a vertical force on the debond force and deformation of two multi-stranded wires bonded to the lingual enamel of lower incisor teeth. Two different stainless steel wires were used, 0.016 × 0.022 inch (Bond-A-Braid® Reliance Orthodontic Products) and a three-stranded 0.0175 inch wire (Ortho Technology). An in vitro model was used to simulate a vertical force at the interdental wire. Twenty-six pairs of incisors were placed in two groups. A 15 mm length of wire was bonded to the lingual surfaces of each pair of incisors using a common bonding technique. A vertical force was applied to the midpoint of the interdental wire, using an Instron universal testing machine. The failure characteristics examined included the maximum force for debond, the degree of wire deformation, and the site of failure. Significance was predetermined at P < 0.05 and multiple comparisons indicated no significant differences (P = 0.147) in the initial mean bond strength between the 0.0175 inch (41.44 N) and 0.016 × 0.022 inch (37.70 N) wires. The main failure type for both the initial and second debond events was fracture of composite bond at the wire-composite interface, cohesive failure. Both wires exhibited similar mean degrees of deflection of 1.30 and 1.51 mm for the 0.0175 inch and 0.016 × 0.022 inch wires, respectively. Rebonding to enamel resulted in significantly lower (P = 0.001) mean bond strength for both wires, 0.0175 inch (13.86 N) and 0.016 × 0.022 inch (14.17 N) in comparison with the initial bond strength. Rebonding to previously bonded enamel may be unpredictable and may lead to higher failure rates of bonded lingual retainers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

OBJECTIVE We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. METHODS We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III...

متن کامل

In vitro debonding of orthodontic retainers analyzed with finite element analysis.

OBJECTIVE The aim of this in vitro study was to determine the load and deflection at failure of different lingual retainers bonded with composite to enamel in a standardized three-point bending test. The results were rationalized with finite element analysis (FEA) models. MATERIALS AND METHODS Four types of multistranded wires, Dead Soft Respond, Twisted ligature, Penta-One, Gold-plated Penta...

متن کامل

Enamel Surface Roughness after Orthodontic Bracket Debonding and Composite Resin Removal by Two Types of Burs

  Objective: Increased enamel surface roughness following orthodontic bracket debonding leads to increased plaque accumulation and enamel decalcification. Therefore, different methods are employed to achieve smoother enamel surfaces after bracket debonding. This study compared enamel surface roughness following orthodontic bracket debonding and composite resin removal using white stone and tung...

متن کامل

Shear bond strength of different retainer wires and bonding adhesives in consideration of the pretreatment process

INTRODUCTION We aimed to compare the shear bond strength (SBS) of three different retainer wires and three different bonding adhesives in consideration of the pretreatment process of enamel surface sandblasting. METHODS 400 extracted bovine incisors were divided into 10 groups of 20 paired specimens each. 10 specimens of each group were pretreated by enamel sandblasting. The retainer wires Bo...

متن کامل

Evaluation of the effects of different groove length and thickness of the retainers on the retention of maxillary anterior base metal resin bonded retainers-an in vitro study

OBJECTIVES The resin-bonded fixed partial dentures have gained immense popularity in recent years as they are more conservative, esthetic, economic and easily fabricated. However debonding is considered the most common cause of failure of resin bonded prosthesis. The objective of the study were to compare the effects of different groove lengths and thickness of retainers on retention of maxilla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 32 6  شماره 

صفحات  -

تاریخ انتشار 2010