Computed tomography model-based treatment of atrial fibrillation and atrial macro-re-entrant tachycardia

نویسندگان

  • Christopher Piorkowski
  • Simon Kircher
  • Arash Arya
  • Thomas Gaspar
  • Masahiro Esato
  • Sam Riahi
  • Andreas Bollmann
  • Daniela Husser
  • Charlotte Staab
  • Philipp Sommer
  • Gerhard Hindricks
چکیده

AIMS Accurate orientation within true three-dimensional (3D) anatomies is essential for the successful radiofrequency (RF) catheter ablation of atrial fibrillation (AF) and atrial macro-re-entrant tachycardia (MRT). In this prospective study, ablation of AF and MRT was performed exclusively using a pre-acquired and integrated computed tomography (CT) image for anatomical 3D orientation without electro-anatomic reconstruction of the left atrium (LA). METHODS AND RESULTS Fifty-four consecutive patients suffering from AF (n = 36) and/or MRT (n = 18) underwent RF catheter ablation. A 3D CT image was registered into the NavX-Ensite system without reconstruction of the atrial chamber anatomy. The quality of CT alignment was assessed and validated according to fluoroscopy information, electrogram characteristics, and tactile feedback at 31 pre-defined LA control points. The ablation of AF as well as mapping and ablation of MRT was performed within the 3D CT anatomy. In all patients, mapping and ablation could be performed without the reconstruction of the respective atrial chamber anatomy. The overall CT alignment was highly accurate with true surface contact in 90% (84%; 100%) of the control points. Complete isolation of all pulmonary vein (PV) funnels was achieved in 35 of 36 patients (97%) with AF. In patients with persistent AF (n = 11), additional isolation of the posterior LA (box lesion) and the placement of a mitral isthmus line were performed. The MRT mechanisms were as follows: around a PV ostium (n = 6), perimitral (n = 4), through LA roof (n = 5), septal (n = 2), and around left atrial appendage (n = 1). After a follow-up of 122 +/- 33 days, 22/25 (88%) patients with paroxysmal AF, 8/11 (73%) with persistent AF, and 16/18 (89%) with MRT remained free from arrhythmia recurrences. CONCLUSION For patients with AF and MRT, our study shows the feasibility of successful placement of complex linear ablation line concepts guided by an integrated 3D image anatomy alone rather than catheter-based virtual chamber surface reconstructions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Supraventricular tachycardia. ECG diagnosis and anatomy.

This paper reviews the anatomical substrates responsible for the induction and maintenance of supraventricular tachycardia and discusses the ECG findings associated with these tachycardias. The normal anatomy of the supraventricular conducting system, particularly within the atria, is complex with conduction proceeding along preferential pathway, which are in turn determined in part by the anis...

متن کامل

Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation: electroanatomic characterization and treatment.

OBJECTIVES The purpose of this study was to evaluate the electroanatomic characteristics of left atrial tachycardia (AT) in a series of patients who underwent circumferential pulmonary vein ablation (CPVA) and to describe the ablation strategy and clinical outcome. BACKGROUND Circumferential pulmonary vein ablation is an effective treatment for atrial fibrillation. A potential midterm complic...

متن کامل

Using electrocardiographic activation time and diastolic intervals to separate focal from macro-re-entrant atrial tachycardias.

OBJECTIVES This study was designed to separate focal from atypical macro-re-entrant atrial tachycardia (AT) on the electrocardiogram (ECG). BACKGROUND Focal AT often cannot be distinguished from macro-re-entrant AT until the time of electrophysiology study (EPS). We hypothesized that quantitative ECG metrics should separate focal AT, using its short activation relative to tachycardia cycle le...

متن کامل

Automatic tachycardia recognition.

A microcomputer algorithm for tachycardia identification, suitable for use in an implanted antitachycardia pacemaker, is described. The system employs an atrial and ventricular electrogram, detects a sustained fast rate in either chamber, and awakens the main program to perform detailed analysis of the tachycardia and its immediately preceding beats. The algorithm distinguishes atrial, ventricu...

متن کامل

Use of non-contact mapping in the treatment of right atrial tachycardias in patients with and without congenital heart disease.

AIMS Right atrial (RA) tachycardias may involve several mechanisms other than typical isthmus-dependent flutters, particularly in patients with congenital heart disease (CHD) or structural heart disease. We aimed at investigating the clinical utility of non-contact mapping in the diagnosis and ablation of these complex arrhythmias. METHODS AND RESULTS Non-contact mapping was used to treat RA ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2008