Acceleration of Tear Film Map Definition on Multicore Systems
نویسندگان
چکیده
Dry eye syndrome is a public health problem, and one of the most common conditions seen by eye care specialists. Among the clinical tests for its diagnosis, the evaluation of the interference patterns observed in the tear film lipid layer is often employed. In this sense, tear film maps illustrate the spatial distribution of the patterns over the whole tear film and provide useful information to practitioners. However, the creation of a single map usually takes tens of minutes. Medical experts currently demand applications with lower response time in order to provide a faster diagnosis for their patients. In this work, we explore different parallel approaches to accelerate the definition of the tear film map by exploiting the power of today’s ubiquitous multicore systems. They can be executed on any multicore system without special software or hardware requirements. The experimental evaluation determines the best approach (on-demand with dynamic seed distribution) and proves that it can significantly decrease the runtime. For instance, the average runtime of our experiments with 50 real-world images on a system with AMD Opteron processors is reduced from more than 20 minutes to one minute and 12 seconds.
منابع مشابه
Parallel definition of tear film maps on distributed-memory clusters for the support of dry eye diagnosis
BACKGROUND AND OBJECTIVES The analysis of the interference patterns on the tear film lipid layer is a useful clinical test to diagnose dry eye syndrome. This task can be automated with a high degree of accuracy by means of the use of tear film maps. However, the time required by the existing applications to generate them prevents a wider acceptance of this method by medical experts. Multithread...
متن کاملA novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.
PURPOSE To report a novel method for pachymetry mapping of human precorneal tear film using Pentacam. METHODS Precorneal tear film is routinely undetected by Pentacam but could be well visualized with the aid of fluorescein. Twenty patients with dry eye and 20 age-matched control subjects with normal eyes were enrolled in this prospective study. The right eye of each subject was scanned once ...
متن کاملDesign of a novel congestion-aware communication mechanism for wireless NoC architecture in multicore systems
Hybrid Wireless Network-on-Chip (WNoC) architecture is emerged as a scalable communication structure to mitigate the deficits of traditional NOC architecture for the future Multi-core systems. The hybrid WNoC architecture provides energy efficient, high data rate and flexible communications for NoC architectures. In these architectures, each wireless router is shared by a set of processing core...
متن کاملPlatforms and Applications in Hardware Security: Trends and Challenges
This paper introduces a few research studies being conducted that are using multicore embedded systems, highlighting the challenges and questions relevant to R&D (Research and Development) in computer systems architecture, focusing on design aspects and optimization of embedded systems that needs to run security solutions or cryptographical algorithms using hardware acceleration, aiming for goo...
متن کاملScalable Lossless High Definition Image Coding on Multicore Platforms
With the advent of multicores in all processor segments including mobile, embedded, desktop and server ones, we are in the new era of multiplying computing power via scaling the number of cores. The multicore approach is more versatile and programmable than the ASIC approach. For instance, the same multicore product can be adapted to the ever-improving potpourri image processing standards. Deve...
متن کامل