Mammalian electron transferring flavoprotein.flavoprotein dehydrogenase complexes observed by microelectrospray ionization-mass spectrometry and surface plasmon resonance.
نویسندگان
چکیده
Microelectrospray ionization-mass spectrometry was used to directly observe electron transferring flavoprotein.flavoprotein dehydrogenase interactions. When electron transferring flavoprotein and porcine dimethylglycine dehydrogenase or sarcosine dehydrogenase were incubated together in the absence of substrate, a relative molecular mass corresponding to the flavoprotein.electron transferring flavoprotein complex was observed, providing the first direct observation of these mammalian complexes. When an acyl-CoA dehydrogenase family member, human short chain acyl-CoA dehydrogenase, was incubated with dimethylglycine dehydrogenase and electron transferring flavoprotein, the microelectrospray ionization-mass spectrometry signal for the dimethylglycine dehydrogenase.electron transferring flavoprotein complex decreased, indicating that the acyl-CoA dehydrogenases have the ability to compete with the dimethylglycine dehydrogenase/sarcosine dehydrogenase family for access to electron transferring flavoprotein. Surface plasmon resonance solution competition experiments revealed affinity constants of 2.0 and 5.0 microm for the dimethylglycine dehydrogenase-electron transferring flavoprotein and short chain acyl-CoA dehydrogenase-electron transferring flavoprotein interactions, respectively, suggesting the same or closely overlapping binding motif(s) on electron transferring flavoprotein for dehydrogenase interaction.
منابع مشابه
Novel protein-protein interactions of the Yersinia pestis type III secretion system elucidated with a matrix analysis by surface plasmon resonance and mass spectrometry.
Binary complexes formed by components of the Yersinia pestis type III secretion system were investigated by surface plasmon resonance (SPR) and matrix-assisted laser desorption time-of-flight mass spectrometry. Pairwise interactions between 15 recombinant Yersinia outer proteins (Yops), regulators, and chaperones were first identified by SPR. Mass spectrometry confirmed over 80% of the protein-...
متن کاملA dielectric barrier discharge ionization based interface for online coupling surface plasmon resonance with mass spectrometry.
The online combination of surface plasmon resonance (SPR) with mass spectrometry (MS) could be beneficial for accurately acquiring molecular interaction data simultaneously with their structural information at high throughputs. In this work, a novel SPR-MS interface was developed using a dielectric barrier discharge ionization (DBDI) source. The DBDI source was placed in front of the MS inlet, ...
متن کاملModified DNA Aptamer Immobilization via Cu(I)-Stabilizing Ligand-assisted Azide-Alkyne Cycloaddition for Surface Plasmon Resonance Measurement
The synthesis and binding integrity of an ErbB2-binding modified DNA aptamer (E2Ap) with 5-naphtyl-20deoxyuridine is confirmed by electrospray ionization mass spectrometry and by a P dot blotting experiment. E2Ap degradation in a conventional Cu(I)-catalyzed azide–alkyne cycloaddition (CuAAC) condition is efficiently prevented by using tris(3-hydroxypropyltriazolylmethyl)amine (THPTA). The immo...
متن کاملDirect Observation of Biomolecular Complexes by Cold-Spray Ionization Time-of-Flight Mass Spectrometry
Many biological processes are regulated by the specific and noncovalent intermolecular recognition between enzyme–substrate, antigen–antibody, receptor–ligand, carbohydrate–protein, and carbohydrate–carbohydrate. The direct observation of these biomolecular interactions is important for understanding the mechanisms behind these biological processes. Electrospray ionization mass spectrometry (ES...
متن کاملDetection and Identification of Bioanalytes with High Resolution LSPR Spectroscopy and MALDI Mass Spectrometry.
High resolution localized surface plasmon resonance (HR-LSPR) sensors were combined with matrix assisted laser desorption ionization mass spectrometry (MALDI-MS) for the first time. LSPR sensors provide real-time label-free detection of molecular adsorption. Subsequent MALDI-MS analysis enables identification of the adsorbed molecules. This synergistic LSPR-MS approach was applied to the detect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of biological chemistry
دوره 279 14 شماره
صفحات -
تاریخ انتشار 2004