Regionally Discrete Aqueous Humor Outflow Quantification Using Fluorescein Canalograms.
نویسندگان
چکیده
PURPOSE To visualize and quantify conventional outflow directly in its anatomic location. METHODS We obtained fluorescein canalograms in six porcine whole eyes and six porcine anterior segment cultures. Eyes were perfused with a constant pressure of 15 mmHg using media containing 0.017 mg/ml fluorescein. Flow patterns were visualized using a stereo dissecting microscope equipped for fluorescent imaging. Images were captured every 30 seconds for 20 minutes for time lapse analysis. Anterior chamber cultures were imaged again on day three of culture. Canalograms were first analyzed for filling time per quadrant. We then wrote a program to automatically compute focal flow fits for each macropixel and to detect convergent perilimbal flow patterns with macropixels grouped into 3 equal-radial width rings around the cornea. A generalized additive model was used to determine fluorescence changes of individual macropixels. RESULTS The resulting imaging algorithm deployed 1024 macropixels that were fit to determine maximum intensity and time to fill. These individual fits highlighted the focal flow function. In whole eyes, significantly faster flow was seen in the inferonasal (IN) and superonasal (SN) quadrants compared to the superotemporal (ST) and inferotemporal (IT) ones (p<0.05). In anterior chamber cultures, reduced flow on day 1 increased in all quadrants on day 3 except in IT (p<0.05). Perilimbal ring analysis uncovered convergent perilimbal flow. CONCLUSIONS An algorithm was developed that analyzes regional and circumferential outflow patterns. This algorithm found flow patterns that changed over time and differ in whole eyes and anterior segment cultures.
منابع مشابه
Noninvasive assessment of aqueous humor turnover in the mouse eye.
PURPOSE To develop a noninvasive test for monitoring changes in aqueous humor turnover in the mouse eye. METHODS After topical instillation of fluorescein, the rate of decay of fluorescence from aqueous humor and cornea was monitored in Black Swiss, C57 Bl6, and DBA 2J mice with a microscope equipped with epifluorescence and a charge-coupled device (CCD) camera. RESULTS The rate of decay of...
متن کاملQuantification of Focal Outflow Enhancement Using Differential Canalograms
PURPOSE To quantify regional changes of conventional outflow caused by ab interno trabeculectomy (AIT). METHODS Gonioscopic, plasma-mediated AIT was established in enucleated pig eyes. We developed a program to automatically quantify outflow changes (R, package eye-canalogram, github.com) using a fluorescent tracer reperfusion technique. Trabecular meshwork (TM) ablation was demonstrated with...
متن کاملEffects of Al3+ and Be2+ ions combined with NaF on ciliary process adenylyl cyclase activity and aqueous humor dynamics in the rabbit eye.
PURPOSE The activity of Al3+, Ga3+, and Be2+ ions in the presence of NaF to directly activate G-proteins was investigated by their potentiative effect on forskolin (FSK)-activated adenylyl cyclase in rabbit ciliary process membranes and their effects on aqueous humor dynamics in vivo. METHODS Adenylyl cyclase (AC) was determined by radiometric conversion of ATP to cAMP by the particulate frac...
متن کاملAqueous Angiography with Fluorescein and Indocyanine Green in Bovine Eyes
PURPOSE We characterize aqueous angiography as a real-time aqueous humor outflow imaging (AHO) modality in cow eyes with two tracers of different molecular characteristics. METHODS Cow enucleated eyes (n = 31) were obtained and perfused with balanced salt solution via a Lewicky AC maintainer through a 1-mm side-port. Fluorescein (2.5%) or indocyanine green (ICG; 0.4%) were introduced intracam...
متن کاملAssumption constraints of fluorophotometry in human eyes.
We read with great interest the article entitled “Fluorophotometric Study of the Effect of the Glaukos Trabecular Microbypass Stent on Aqueous Humor Dynamics” by Fernández-Barrientos et al. The authors examined aqueous humor dynamics before and after surgery in eyes undergoing cataract surgery and the implantation of the bypass stent (group 1) and in eyes undergoing cataract surgery alone (grou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- PloS one
دوره 11 3 شماره
صفحات -
تاریخ انتشار 2016