Experimental brain abscess: enhanced sonography and pathologic correlation.

نویسندگان

  • D R Enzmann
  • B E Lyons
  • B Carroll
  • R C Placone
  • J Rasor
  • R H Britt
  • J Buxton
  • D Wilson
چکیده

A new sonographic contrast agent, gelatin-encapsulated nitrogen microbubbles, was introduced intraarterially to enhance the high-resolution sonographic scan of an experimental brain abscess. The echogenicity produced by the microbubbles correlated closely to the site and distribution of abscess neovascularity. The contrast agent aided in the detection of small necrotic centers in the late stages of abscess evolution when these centers were not visualized on noncontrast sonograms. The echogenic effect of the microbubbles was maximum immediately after injection; it decreased by 5 min and had virtually disappeared at 15 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT versus sonography for monitoring radiofrequency ablation in a porcine liver.

OBJECTIVE The objective of this study was to compare CT and sonography for monitoring radiofrequency (RF) lesions in porcine livers. SUBJECTS AND METHODS RF lesions (n = 12) were created in three pig livers by applying 13 min of current to a multielectrode RF probe with a target temperature of 95 degrees C. Helical unenhanced CT and corresponding axial sonography were performed before ablatio...

متن کامل

Intracranial hemorrhage in premature infants: sonographic-pathologic correlation.

Spontaneous intracranial hemorrhage is the most common central nervous system abnormality in premature infants. In this report the cranial sonographic and pathologic findings of 25 autopsied premature infants are correlated. The presence and size of subependymal, intraventricular, and intraparenchymal hemorrhage were well documented by sonography. Cerebellar, choroid plexus, and cortical hemorr...

متن کامل

Magnetic resonance imaging in focal liver lesions: Imaging with pathological correlation

Background: Magnetic resonance signal intensity of focal liver lesions is affected by numerous pathologic factors. Lesion histologic features, such as cellularity, vascularity, stromal component, and intratumoral necrosis or hemorrhage, strongly affect T1 and T2 relaxation times. Aim: Our study is done to assess the lesion characterization potential of MRI by evaluating unenhanced and dynamic g...

متن کامل

Primary central nervous system lymphoma: CT and pathologic correlation.

CT findings of 15 patients with histologically proven primary central nervous system (CNS) lymphoma were reviewed with pathologic correlation in order to evaluate variable CT patterns. There were a total of 32 lesions. Of the 15 patients studied, seven had acquired immunodeficiency syndrome (AIDS), all diagnosed within the past 3 years. The CT observations of eight non-AIDS patients were consis...

متن کامل

Intracranial Serratia infection in preterm newborn infants.

Four cases of cerebral Serratia infection in preterm infants were diagnosed with the aid of real-time sector sonography. Three cases had brain abscesses and one case had ventriculitis. In two cases brain abscesses had ruptured into the ventricles. Serratia brain abscess was common in our series of brain abscesses. Sonographic patterns of cerebritis, abscess formation, and ventriculitis correlat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 1982