Local Oscillator Induced Instabilities in Trapped Ion Frequency Standards*

نویسنده

  • G. John Dick
چکیده

The trapped ion frequency source is one of a class of passive atomic frequency standards that necessarily use an ancillary frequency source to interrogate the atomic transition. For passive atomic sources such as Rubidium standards, ultimate long term performance of the source is not dependent on this local oscillator, except to the extent limited by feedback gain. For the trapped ion source this immunity to local oscillator phase noise is lost. In contrast to the Rubidium source, a sequential measurement procedure is used in which the signal from the local oscillator is sensed only some of the time. Since the local oscillator is only periodically sampled, certain short term fluctuations in the local oscillator frequency will give rise to long term fluctuations in the difference between the stabilized local oscillator frequency and that of the atomic absorption. We have performed calculations of the influence of such phase noise fluctuations in the reference oscillator on the performance of the standard as a function of duty cycle for a local oscillator with frequency fluctuations showing a llf spectral density, as is typically shown by crystal Quartz oscillators for long measuring times (1-100 seconds). Expressions are generated for the limiting trapped ion 7-'12 variance due to the local oscillator for various values for the duty factor d. Explicitly treated are the cases d << 1, d = 1 6, (6 << 1) and d = 112. It is seen that for a duty factor < 90%, local oscillator performance equal to that of the ion standard (for a measuring time T equal to the period td of the sampling cycle) will significantly degrade the characteristic r-'I2 passive atomic standard performance. For d near 1, (6 = (1 d) << 1) an approximately linear dependence of this degradation on 6 is found.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Precision Time and Frequency Systems and Devices at Apl

APL's entry into research, development, testing, and fabrication of precision time and frequency devices was occasioned by its development of a high-quality, spaceborne oscillator for the Transit navigation satellite program. Later, this effort branched out into atomic frequency standards and other innovative frequency standards such as the super conducting cavity stability oscillator and trapp...

متن کامل

Miniature Trapped-Ion Frequency Standard with Yb

We describe the development and frequency instability measurements of a highly miniaturized, buffer gas cooled, trapped-ion atomic clock. The clock utilizes the 12.6 GHz hyperfine transition of the Yb ion. A custom-built 3 cm vacuum package containing the ion trap is integrated with other key elements of the atomic frequency standard, including a photo multiplier tube, miniaturized laser source...

متن کامل

Single trapped ion as a time-dependent harmonic oscillator

We show how a single trapped ion may be used to test a variety of important physical models realized as time-dependent harmonic oscillators. The ion itself functions as its own motional detector through laserinduced electronic transitions. Alsing et al., Phys. Rev. Lett. 94, 220401 2005 proposed that an exponentially decaying trap frequency could be used to simulate thermal Gibbons-Hawking radi...

متن کامل

Theoretical study of the Dick effect in a continuously operated Ramsey resonator

It is well established that passive frequency standards operated in pulsed mode may suffer a degradation of their frequency stability due to the frequency (FM) noise of the Local Oscillator (LO). In continuously operated frequency standards, it has been shown that a similar degradation of the frequency stability may arise, depending on the used modulation-demodulation scheme. In this paper, we ...

متن کامل

Improved short-term stability of optical frequency standards: approaching 1 Hz in 1 s with the Ca standard at 657 nm.

For a neutral (40)Ca-based optical frequency standard we report a fractional frequency instability of 4 x 10(-15) in 1 s, which represents a fivefold improvement over existing atomic frequency standards. Using the technique of optical Bordé-Ramsey spectroscopy with a sample of 10(7) trapped atoms, we have resolved linewidths as narrow as 200 Hz (FWHM). With colder atoms this system could potent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002