Registering prostate external beam radiotherapy with a boost from high-dose-rate brachytherapy: a comparative evaluation of deformable registration algorithms

نویسندگان

  • Calyn R. Moulton
  • Michael J. House
  • Victoria Lye
  • Colin I. Tang
  • Michele Krawiec
  • David J. Joseph
  • James W. Denham
  • Martin A. Ebert
چکیده

BACKGROUND Registering CTs for patients receiving external beam radiotherapy (EBRT) with a boost dose from high-dose-rate brachytherapy (HDR) can be challenging due to considerable image discrepancies (e.g. rectal fillings, HDR needles, HDR artefacts and HDR rectal packing materials). This study is the first to comparatively evaluate image processing and registration methods used to register the rectums in EBRT and HDR CTs of prostate cancer patients. The focus is on the rectum due to planned future analysis of rectal dose-volume response. METHODS For 64 patients, the EBRT CT was retrospectively registered to the HDR CT with rigid registration and non-rigid registration methods in VelocityAI. Image processing was undertaken on the HDR CT and the rigidly-registered EBRT CT to reduce the impact of discriminating features on alternative non-rigid registration methods applied in the software suite for Deformable Image Registration and Adaptive Radiotherapy Research (DIRART) using the Horn-Schunck optical flow and Demons algorithms. The propagated EBRT-rectum structures were compared with the HDR structure using the Dice similarity coefficient (DSC), Hausdorff distance (HD) and average surface distance (ASD). The image similarity was compared using mutual information (MI) and root mean squared error (MSE). The displacement vector field was assessed via the Jacobian determinant (JAC). The post-registration alignments of rectums for 21 patients were visually assessed. RESULTS The greatest improvement in the median DSC relative to the rigid registration result was 35 % for the Horn-Schunck algorithm with image processing. This algorithm also provided the best ASD results. The VelocityAI algorithms provided superior HD, MI, MSE and JAC results. The visual assessment indicated that the rigid plus deformable multi-pass method within VelocityAI resulted in the best rectum alignment. CONCLUSIONS The DSC, ASD and HD improved significantly relative to the rigid registration result if image processing was applied prior to DIRART non-rigid registrations, whereas VelocityAI without image processing provided significant improvements. Reliance on a single rectum structure-correspondence metric would have been misleading as the metrics were inconsistent with one another and visual assessments. It was important to calculate metrics for a restricted region covering the organ of interest. Overall, VelocityAI generated the best registrations for the rectum according to the visual assessment, HD, MI, MSE and JAC results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

High-dose-rate brachytherapy boost for prostate cancer: rationale and technique

High-dose-rate brachytherapy (HDR) is a method of conformal dose escalation to the prostate. It can be used as a local boost in combination with external beam radiotherapy, with a high degree of efficacy and low rate of long term toxicity. Data consistently reports relapse free survival rates of greater than 90% for intermediate risk patients and greater than 80% for high risk. Results are supe...

متن کامل

Stereotactic body-radiotherapy boost dose of 18 Gy vs 21 Gy in combination with androgen-deprivation therapy and whole-pelvic radiotherapy for intermediate- or high-risk prostate cancer: a study protocol for a randomized controlled, pilot trial

BACKGROUND Combination therapy using external-beam radiotherapy (EBRT) with a brachytherapy boost has demonstrated superior biochemical control than dose-escalated EBRT alone. Whereas brachytherapy is disadvantageous because it is an invasive procedure, stereotactic body-radiotherapy (SBRT) using CyberKnife could emulate the dose distribution of brachytherapy and is a non-invasive and safe moda...

متن کامل

Prostate external beam radiotherapy combined with high-dose-rate brachytherapy: dose-volume parameters from deformably-registered plans correlate with late gastrointestinal complications

BACKGROUND Derivation of dose-volume correlated with toxicity for multi-modal treatments can be difficult due to the perceived need for voxel-by-voxel dose accumulation. With data available for a single-institution cohort with long follow-up, an investigation was undertaken into rectal dose-volume effects for gastrointestinal toxicities after deformably-registering each phase of a combined exte...

متن کامل

Mapping of dose distribution from IMRT onto MRI-guided high dose rate brachytherapy using deformable image registration for cervical cancer treatments: preliminary study with commercially available software

PURPOSE For patients undergoing external beam radiation therapy (EBRT) and brachytherapy, recommendations for target doses and constraints are based on calculation of the equivalent dose in 2 Gy fractions (EQD2) from each phase. At present, the EBRT dose distribution is assumed to be uniform throughout the pelvis. We performed a preliminary study to determine whether deformable dose distributio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015