Use of balloon aortic valvuloplasty to size the aortic annulus before implantation of a balloon-expandable transcatheter heart valve.

نویسندگان

  • Vasilis C Babaliaros
  • Zahid Junagadhwalla
  • Stamatios Lerakis
  • Vinod Thourani
  • David Liff
  • Edward Chen
  • Thomas Vassiliades
  • Clay Chappell
  • Nathan Gross
  • Ateet Patel
  • Sharon Howell
  • Jacob T Green
  • Emir Veledar
  • Robert Guyton
  • Peter C Block
چکیده

OBJECTIVES Our aim was to describe the use of balloon aortic valvuloplasty (BAV) to select proper transcatheter heart valve (THV) size. BACKGROUND Transesophageal echocardiogram (TEE) measurement alone of the aortic annulus may not be adequate to select a THV size. BAV can more accurately size the aortic annulus. We report our experience using this strategy in patients undergoing THV implantation. METHODS Twenty-seven patients underwent sizing of the aortic annulus by BAV and TEE. We implanted the minimal THV size that was greater than the annulus measured by BAV. RESULTS The annulus measured by TEE was 21.3 +/- 1.6 mm and by BAV was 22.6 +/- 1.8 mm (p < 0.001). The number of balloon inflations was 2.7 +/- 0.7 (range 2 to 4), and the balloon sizes used were 22.0 +/- 1.8 mm (range 20 to 25 mm). Fourteen patients (52%) required upsizing of the initial balloon suggested by TEE; rapid pacing duration was 8 +/- 1.3 s (range 6 to 11 s). No change in aortic insufficiency or hemodynamic instability occurred with BAV. Fifteen patients (56%) received a 23-mm THV; 12 patients a 26-mm THV. No coronary occlusion, annular damage, or THV embolization occurred. Paravalvular leak was grade <or=1 in all patients. In 7 patients (26%), balloon sizing resulted in selection of a specific THV size that could not be done by TEE alone. CONCLUSIONS BAV sizing of the aortic annulus is safe and is an important adjunct to TEE when selecting THV size. Implanting the minimal THV greater than the BAV annulus size resulted in no adverse events. These data suggest that use of BAV for THV selection may improve the safety and efficacy of THV implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prior balloon valvuloplasty versus DIRECT transcatheter Aortic Valve Implantation (DIRECTAVI): study protocol for a randomized controlled trial

BACKGROUND Balloon predilatation of the aortic valve has been regarded as an essential step during the transcatheter aortic valve implantation (TAVI) procedure. However, recent evidence has suggested that aortic valvuloplasty may cause complications and that high success rates may be obtained without prior dilatation of the valve. We hypothesize that TAVI performed without predilatation of the ...

متن کامل

Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis.

AIMS New-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). METHODS AND RESULTS Sixty-five consecutive patients underwent TAVI with cont...

متن کامل

Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size?

OBJECTIVES We sought to study the potential role of balloon aortic valvuloplasty (BAV) in sizing the aortic annulus in patients before transcatheter heart valve (THV) implantation. BACKGROUND Despite clinicians' growing experience with THV procedures, the best method of annulus sizing remains unclear. METHODS Twenty-three patients with aortic stenosis (<1.0 cm(2)) who were undergoing surgic...

متن کامل

بررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی

Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...

متن کامل

Valve implantations on the move

Transcatheter aortic valve implantation (TAVI) has expanded rapidly since the first procedure in 2002. The first randomised control trial showed non inferiority of TAVI compared with surgical aortic valve replacement (AVR) in high-risk patients with severe aortic valve stenosis (AS) and superiority as compared with conservative management, including balloon valvuloplasty [1]. Since 2012, TAVI h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2010