Outcome of anatomic locking plate in extraarticular distal humeral shaft fractures
نویسندگان
چکیده
BACKGROUND Extraarticular fractures of distal humerus are challenging injuries to treat because of complex anatomy and fracture patterns. Functional bracing may not provide adequate stability in these injuries and operative treatment with intramedullary nails or conventional plates also has the limitation of inadequate fixation in the short distal fragment. The 3.5 mm precontoured single column locking plate (extraarticular distal humerus plate [EADHP]) has been introduced to overcome this problem. We evaluated the clinical and functional outcomes of treating these fractures with the EADHP. MATERIALS AND METHODS 26 patients with extraarticular fractures of distal humerus presenting within 3 weeks of injury between January 2012 and June 2015, were included in this prospective study. Open IIIB and IIIC fractures, nonunions, or those with a history of previous infection in the arm were excluded. Operative fixation was done using the EADHP in all the cases. The time for union, range of motion at shoulder and elbow and secondary procedures were recorded in followup. The shoulder and elbow function was assessed using the University of California Los Angeles (UCLA) shoulder scale and Mayo Elbow Performance Score (MEPS) respectively. RESULTS There were 21 males and 5 females with mean age of 37.3 years (range 18-72 years). Twenty two (84.6%) cases had complex fracture patterns (AO/OTA Type 12-B and C). The mean time to fracture union was 22.4 weeks (range 16-28 weeks). The mean followup time was 11.6 months, (range 4-24 months). Four patients (15.4%) had failure of cortical screws in the proximal fracture fragment, of which two required revision fixation with bone grafting. Another nonunion was seen following a surgical site infection, which healed after wound lavage and bone grafting. The MEPS (average: 96.1; range 80-100) was excellent in 81% cases (n = 21) and good in 19% cases (n = 5). UCLA score (average: 33.5; range 25-35) was good/excellent in 88.5% cases (n = 23) and fair in 11.5% cases (n = 3). CONCLUSION EADHP is a reliable option in treating extraarticular distal humeral fractures as it provides stable fixation with an early return to function.
منابع مشابه
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملA simple technique for double plating of extraarticular distal humeral shaft fractures.
Plate fixation of extraarticular distal humeral shaft fracture is often difficult. Traditional techniques do not allow for stable fixation. A single DCP plate may have inadequate purchase in the distal fragment. The use of large plates extending distally over the lateral supracondylar ridge is often associated with pain and sometimes interferes with elbow range of motion. In this study, 22 pati...
متن کاملThe Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma
Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...
متن کاملTips and Techniques- Surgical Fixation of Extra-articular Distal Humerus Fractures with a Posterolateral Locking Compression Plate (LCP)
The appropriate treatment of extraarticular distal humerus fractures is controversial. While functional bracing has been shown to result in good outcomes, some surgeons continue to favor operative fixation. Specifically, they cite concerns of radial nerve injury, difficulty in controlling fracture alignment, and long-term elbow stiffness with bracing. Jawa et al compared functional bracing with...
متن کاملManagement of Humeral Shaft Fractures With Intramedullary Interlocking Nail Versus Locking Compression Plate.
Surgical fixation of humeral shaft fractures generally involves plating or nailing. It is unclear whether one method is more effective than the other. The aim of this study was to compare the results of the intramedullary nail and locking compression plate for the treatment of humeral shaft fractures. A total of 60 patients with humeral shaft fractures were randomized to undergo surgery with an...
متن کامل