Measurements of central corneal thickness using two immersion ultrasound techniques and optical technique.
نویسنده
چکیده
OBJECTIVE To compare the accuracy of central corneal thickness measurements using ultrasound biomicroscopy, Orbscan II tomography and an Artemis-2 very high frequency ultrasound scanner. METHODS The prospective study was conducted at Eye World Centre, Riyadh, Saudi Arabia, from September to November 2012. One eye from each of 60 normal subjects was analysed. The central corneal thickness was measured using ultrasound biomicroscopy, Orbscan II tomography and the Artemis-2 very high frequency ultrasound scanner. Results were compared using analysis of variance, repeated-measures analysis of variance and limits of agreement. RESULTS The mean central corneal thickness was 530.30 +/- 30.75 microm, 548.95 +/- 30.33 microm and 554.73 +/- 31.97 microm for biomicroscopy, tomography and the scanner respectively. The intraobserver repeatability analyses of variance were not significant for the three procedures (p = 0.19, 0.23 and 0.41, respectively). A significant difference was noted among the three different methods (p = 0.0001). However, comparison among instruments revealed no significant difference between tomography and the scanner (p > 0.05), yet significant differences were noted in biomicroscopy vs. tomography, and biomicroscopy vs. the scanner (p < 0.01 and P < 0.001, respectively). The mean differences (and upper/lower limits of agreement) for central corneal thickness measurements were 18.92 +/- 40.71 (60.90/-98.70); 24.7 +/- 13.13 (1.00/-50.40), and -5.80 +/- 38.61 (69.90/-81.40) for biomicroscopy vs. tomography, biomicroscopy vs. scanner, and tomography vs. scanner respectively. CONCLUSIONS The central corneal thickenss measurements obtained using Orbscan II tomography and the Artemis-2 very high frequency ultrasound scanner can be used interchangeably. However, Orbscan II tomography and the Artemis-2 scanner measurements cannot be used interchangeably with ultrasound biomicroscopy.
منابع مشابه
Comparison of artemis 2 ultrasound and Visante optical coherence tomography corneal thickness profiles.
PURPOSE To compare corneal thickness profiles of cross-sections of cornea determined by arc-scanned immersion ultrasound and optical coherence tomography (OCT). METHODS Corneas of 28 eyes from 14 participants were scanned in triplicate using the Artemis 2 high-frequency arc-scanned ultrasound system (ArcScan Inc) and the Visante OCT system (Carl Zeiss Meditec). Corneal thickness and reproduci...
متن کاملCentral corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy.
PURPOSE To compare central corneal thickness measurements made using two different methods, optical coherence tomography (OCT) and ultrasound pachymetry, applied both in normal eyes and in eyes on which photorefractive keratectomy (PRK) had been performed. A second objective was to assess the intrasession variability of OCT measurements. METHODS In this prospective study, central corneal thic...
متن کاملRepeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.
PURPOSE To assess the three-dimensional repeatability of thickness measurements for epithelium, stroma, cornea, flap, and residual stromal bed using the Artemis very high-frequency (VHF) digital ultrasound arc-scanner (ArcScan Inc). METHODS Five consecutive measurements were obtained for 10 eyes of 10 patients 1 year after LASIK using the Artemis VHF digital ultrasound arc-scanner across the ...
متن کاملComparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
BACKGROUND The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomography (AS-OCT) system, and a high-frequency ultrasound biomicroscopy (HF-UBM) system. METHODS Fifty...
متن کاملComparison of optical and ultrasound central corneal pachymetry.
In 100 eyes of 50 patients central corneal thickness was measured comparing optical to ultrasound pachymetry. With optical pachymetry the values were 1 to 40 micrometer (microns) lower in 64 eyes compared to ultrasound pachymetry. With ultrasound pachymetry the values were 1 to 18 microns lower in 26 eyes compared to optical pachymetry. In 10 cases no difference in pachymetry readings was seen ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JPMA. The Journal of the Pakistan Medical Association
دوره 64 3 شماره
صفحات -
تاریخ انتشار 2014