Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams

نویسندگان

  • Stephen M. Seltzer
  • Paul M. Bergstrom
چکیده

Monte Carlo photon-electron transport calculations have been done to derive new wall corrections for the six NBS-NIST standard graphite-wall, air-ionization cavity chambers that serve as the U.S. national primary standard for air kerma (and exposure) for gamma rays from (60)Co, (137)Cs, and (192)Ir sources. The data developed for and from these calculations have also been used to refine a number of other factors affecting the standards. The largest changes are due to the new wall corrections, and the total changes are +0.87 % to +1.11 % (depending on the chamber) for (60)Co beams, +0.64 % to +1.07 % (depending on the chamber) for (137)Cs beams, and -0.06 % for the single chamber used in the measurement of the standardized (192)Ir source. The primary standards for air kerma will be adjusted in the near future to reflect the changes in factors described in this work.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams

Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray referenc...

متن کامل

Comparison of the air kerma standards for 137 Cs and 60 Co gamma - ray beams between the IAEA and the NIST

A comparison of the air kerma standards for Cs and Co gamma ray beams was performed between the NIST and the IAEA. Two reference class ionization chambers owned by the IAEA were used as part of this comparison and were calibrated at each facility. The calibration coefficients, NK, were determined for both chambers and in both gamma-ray beams. The measurements were performed at the IAEA and NIST...

متن کامل

The effect of scattered photons for x-ray air-kerma calibrations

The parallel-plate free-air ionization chambers are used for X-rays air-kerma rate standards at National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST). The diaphragms are used to free-air chambers to fix the air volume of ionizing region in chambers. It means that absolute air-kerma rates are defined for collimated x-ray beams, beca...

متن کامل

Validation testing of ANSI/IEEE n42.49 standard requirements for personal emergency radiation detectors.

Various radiation detectors including electronic personal emergency radiation detectors (PERDs), radiochromic film cards and thermoluminescent dosimeters (TLDs) were used to validate a subset of the radiological test requirements listed in the American National Standards Institute/The Institute of Electrical and Electronic Engineers (ANSI/IEEE) N42.49 standard. The subset of tests included the ...

متن کامل

Radiation attenuation by lead and nonlead materials used in radiation shielding garments.

The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Research Council of Canada, air kerma measurements were used to compare a variety ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 108  شماره 

صفحات  -

تاریخ انتشار 2003