Robust and Accurate Coronary Artery Centerline Extraction in CTA by Combining Model-Driven and Data-Driven Approaches

نویسندگان

  • Yefeng Zheng
  • Hüseyin Tek
  • Gareth Funka-Lea
چکیده

Various methods have been proposed to extract coronary artery centerlines from computed tomography angiography (CTA) data. Almost all previous approaches are data-driven, which try to trace a centerline from an automatically detected or manually specified coronary ostium. No or little high level prior information is used; therefore, the centerline tracing procedure may terminate early at a severe occlusion or an anatomically inconsistent centerline course may be generated. Though the connectivity of coronary arteries exhibits large variations, the position of major coronary arteries relative to the heart chambers is quite stable. In this work, we propose to exploit the automatically segmented chambers to 1) predict the initial position of the major coronary centerlines and 2) define a vessel-specific region-of-interest (ROI) to constrain the following centerline refinement. The proposed prior constraints have been integrated into a model-driven algorithm for the extraction of three major coronary centerlines, namely the left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA). After extracting the major coronary arteries, the side branches are traced using a data-driven approach to handle large anatomical variations in side branches. Experiments on the public Rotterdam coronary CTA database demonstrate the robustness and accuracy of the proposed method. We achieve the best average ranking on overlap metrics among automatic methods and our accuracy metric outperforms all other 22 methods (including both automatic and semi-automatic methods).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model-Driven Centerline Extraction for Severely Occluded Major Coronary Arteries

Almost all previous approaches on coronary artery centerline extraction are data-driven, which try to trace a centerline from an automatically detected or manually specified coronary ostium. No or little high level prior information is used; therefore, the centerline tracing procedure may terminate early at a severe occlusion or an anatomically inconsistent centerline course may be generated. I...

متن کامل

Task-space Control of Electrically Driven Robots

Actuators of robot operate in the joint-space while the end-effect or of robot is controlled in the task-space. Therefore, designing a control system for a robotic system in the task-space requires the jacobian matrix information for transforming joint-space to task-space, which suffers from uncertainties. This paper deals with the robust task-space control of electrically driven robot manipula...

متن کامل

Two Point Minimum Cost Path Approach for CTA Coronary Centerline Extraction

In this work a minimum cost path approach is adopted to extract coronary artery centerlines from CTA data. The algorithm depends on the manual definition of the start and end point of the vessel. The cost image used in the minimal cost path approach is based on a vesselness measure and a smooth window function on intensity. In the majority of the cases the method was able to extract the centerl...

متن کامل

Robust Fractional-order Control of Flexible-Joint Electrically Driven Robots

This paper presents a novel robust fractional PIλ controller design for flexible joint electrically driven robots. Because of using voltage control strategy, the proposed approach is free of problems arising from torque control strategy in the design and implementation. In fact, the motor's current includes the effects of nonlinearities and coupling in the robot manipulator. Therefore, cancella...

متن کامل

Adaptive RBF network control for robot manipulators

TThe uncertainty estimation and compensation are challenging problems for the robust control of robot manipulators which are complex systems. This paper presents a novel decentralized model-free robust controller for electrically driven robot manipulators. As a novelty, the proposed controller employs a simple Gaussian Radial-Basis-Function Network as an uncertainty estimator. The proposed netw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 16 Pt 3  شماره 

صفحات  -

تاریخ انتشار 2013