Accuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study
نویسندگان
چکیده
Introduction Evaluation of accuracy, precision, and trending ability of cardiac index (CI) measurements using the Aesculon™ bioimpedance electrical cardiometry (Aesc) compared to the continuous pulmonary artery thermodilution catheter (PAC) technique before, during, and after cardiac surgery. Methods A prospective observational study with fifty patients with ASA 3-4. At six time points (T), measurements of CI simultaneously by continuous cardiac output pulmonary thermodilution and thoracic bioimpedance and standard hemodynamics were performed. Analysis was performed using Bland-Altman, four-quadrant plot, and polar plot methodology. Results CI obtained with pulmonary artery thermodilution and thoracic bioimpedance ranged from 1.00 to 6.75 L min-1 and 0.93 to 7.25 L min-1, respectively. Bland-Altman analysis showed a bias between CIBIO and CIPAC of 0.52 liters min-1 m-2, with LOA of [-2.2; 1.1] liters min-1 m-2. Percentage error between the two techniques was above 30% at every time point. Polar plot methodology and 4-quadrant analysis showed poor trending ability. Skin incision had no effect on the results. Conclusion CI obtained by continuous PAC and CI obtained by Aesculon bioimpedance are not interchangeable in cardiac surgical patients. No effects of skin incision were found. International clinical trial registration number is ISRCTN26732484.
منابع مشابه
Comparison of Cardiac Output Measurement by Noninvasive Methodwith Electrical Cardiometry and Invasive Method with Thermodilution Technique in Patients Undergoing Coronary Artery Bypass Grafting
Objective: This study was conducted to compare the cardiac output by using Electrical Cardiometry (EC), a noninvasive method of continuous cardiac output monitoring during cardiac surgery with pulmonary artery catheter (PAC) derived cardiac output. Design: Prospective observational clinical study. Setting: Cardiac surgery operating room of a tertiary care cardiac center. Participants: Twenty fi...
متن کاملRadial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery.
OBJECTIVES Radial artery applanation tonometry allows completely noninvasive continuous cardiac output estimation. The aim of the present study was to compare cardiac output measurements obtained with applanation tonometry (AT-CO) using the T-Line system (Tensys Medical, San Diego, CA) with cardiac output measured by intermittent pulmonary artery thermodilution using a pulmonary artery catheter...
متن کاملCorrelation of Electric Cardiometry and Continuous Thermodilution Cardiac Output Monitoring Systems
Purpose: Impedance Cardiography (ICG) with its drawbacks to reliably estimate cardiac output (CO) when compared to reference methods has led to the development of a novel technique called Electrical Cardiometry (EC). The purpose of this study was to compare EC-CO with the Continuous CO (CCO) derived from Pulmonary Artery Catheter (PAC). Methods: 60 patients scheduled to undergo coronary artery ...
متن کاملCross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters
INTRODUCTION Although less invasive than pulmonary artery catheters (PACs), arterial pulse pressure analysis techniques for estimating cardiac output (CO) have not been simultaneously compared to PAC bolus thermodilution CO (COtd) or continuous CO (CCO) devices. METHODS We compared the accuracy, bias and trending ability of LiDCO™, PiCCO™ and FloTrac™ with PACs (COtd, CCO) to simultaneously t...
متن کاملComparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output.
OBJECTIVE Continuous measurement of cardiac output (CCO) is of great importance in the critically ill. However, pulmonary artery thermodilution has been questioned for possible complications associated with right heart catheterization. Furthermore, measurements are delayed in the continuous mode during rapid hemodynamic changes. A new pulmonary artery catheter CCO device (Aortech, Bellshill, Sc...