Repeatability of vascular responsiveness measures derived from near‐infrared spectroscopy
نویسندگان
چکیده
Near-infrared spectroscopy (NIRS)-derived measures of tissue oxygen saturation (StO2) have been recently shown to significantly correlate with the widely used method for noninvasively assessing vascular endothelial function, flow-mediated dilation (FMD). The purpose of this study was to examine the intraday and interday reliability of the reperfusion slope of StO2 (slope 2 StO2) and compare it to FMD Ultrasound-derived FMD was quantified following 5 min of distal cuff occlusion of the popliteal artery in nine healthy young men (26 ± 3 years). An FMD test was performed each of 4 days, with a fifth involving three tests. FMD was calculated as the greatest percent change in diameter from baseline (%FMD). StO2 was measured using NIRS throughout each test, with slope 2 StO2 being calculated as the upslope of 10-sec following cuff release. Reliability was determined using repeatability, intraclass correlation coefficients (ICC), and coefficient of variation (CV). Repeatability of slope 2 StO2 was better than %FMD for both intraday (0.43 and 5.65, respectively) and interday (0.48 and 4.82, respectively) comparisons; approximately 30% of mean values for slope 2 StO2 could be attributed to measurement error, whereas 100% of mean FMD could be for both intraday and interday comparisons. Similarly, ICC and CV values indicated stronger reliability of slope 2 StO2 compared to %FMD for both intraday (ICC 0.92 and 0.36, respectively; CV 9 ± 4% and 44 ± 24%, respectively) and interday (ICC 0.94 and 0.25, respectively; CV 14 ± 5% and 40 ± 22%, respectively) comparisons. In conclusion, NIRS-derived slope 2 StO2 can be used as a reliable measure of vascular reactivity.
منابع مشابه
Near infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care
Near infrared spectroscopy of the thenar eminence (NIRSth) is a noninvasive bedside method for assessing tissue oxygenation. The NIRS probe emits light with several wavelengths in the 700- to 850-nm interval and measures the reflected light mainly from a predefined depth. Complex physical models then allow the measurement of the relative concentrations of oxy and deoxyhemoglobin, and thus tissu...
متن کاملDevelopment of optimal protocol for visible and near-infrared reflectance spectroscopic evaluation of meat quality.
The present experiments were conducted to develop an optimal protocol for visible and near-infrared reflectance spectroscopic evaluation of meat quality. It was determined that spectra were more repeatable using a 35 mm-diameter high-intensity reflectance probe rather than a 3 mm-diameter reflectance probe. Using the high-intensity reflectance probe, spectra were generally very repeatable (e.g....
متن کاملPotential of Near-Infrared Reflectance Spectroscopy (NIRS) to Predict Nutrient Composition of Bromus tomentellus
Determination of forage quality of available species is one of the fundamentalfactors for the management of rangelands. Near-Infrared Reflectance Spectroscopy (NIRS)was used to analysis the Nitrogen (N), Acid Detergent Fiber (ADF), Dry MatterDigestibility (DMD) and Metabolizable Energy (ME) content of three phenological stages(vegetative, flowering and seeding) of Bromus tomentellus samples in ...
متن کاملNear-Infrared Spectroscopy System for Monitoring Peripheral Vascular Disease
In this project, a non-invasive near-infrared spectroscopy system is developed. It is tailored to monitor tissue oxygenation and total hemoglobin concentration in the limbs. The system would be especially useful in diabetic patients where blood circulation is poor in the extremities, and oxygenation is lower limiting the ability of the tissue to have proper function. It is crucial to monitor hi...
متن کاملInvestigation of the Potential of Near Infrared Spectroscopy for the Detection and Quantification of Pesticides in Aqueous Solution
This research investigates the potential of near infrared spectroscopy (NIRS) for the detection and quantification of pesticides in aqueous solution. Standard solutions of Alachlor and Atrazine (ranging in concentration from 1.25 100 ppm) were prepared by dilution in a Methanol/water solvent (1:1 methanol/water (v/v)). Near infrared transmission spectra were obtained in the wavelength region 40...
متن کامل