Optic Fracture of the Preloaded Intraocular Lens during Insertion

نویسندگان

  • Ja Young Lee
  • Jin Young Kim
چکیده

Dear Editor, Intraocular lens (IOL) fracture is a relatively rare complication of cataract surgery during IOL implantation [1]. Foldable IOLs specifically are often fractured by either forceps or injector systems during IOL loading [2,3]. To improve the efficacy and safety of cataract surgery, many preloaded IOLs have been developed and are widely used. Here, we report the first optic fracture in a preloaded IOL during posterior chamber, hydrophobic, acrylic IOL insertion. A 75-year-old male patient was admitted for left eye cataract surgery. He had no recent systemic disease and no history of ocular trauma. During surgery, the lens nucleus was successfully removed. For IOL insertion, we prepared a preloaded, three-piece IOL (Hoya iSert PS AF-1 [UV], PC-60AD; Hoya, Tokyo, Japan) (Fig. 1A) after removal of the remnants of both the epinucleus and cortex (Fig. 1B). We lubricated the iSert system inside (Hoya) case. We firmly grasped the body and slowly inserted the system in one continuous motion using the slider. We gently pushed the plunger forward and slowly rotated the iSert system clockwise in order to engage the threads and allow insertion of the IOL (Fig. 1C and 1D). However, during IOL insertion, we heard a cracking sound. Upon investigation, we found that the IOL optic had unfolded and broken into two pieces, with small posterior capsule rupture (Fig. 1E and 1F). We widened the corneal incision and withdrew the IOL from the chamber (Fig. 1G and 1H). After ensuring that there had been no loss of vitreous, a three-piece IOL was fixed inside the ciliary sulcus, and we successfully completed the cataract surgery (Fig. 1I). There were no further postoperative complications in the 3 months following surgery. Our case is unique due to optic fracture of the preloaded IOL during IOL insertion. The IOL was a three-piece lens with a 6.0-mm hydrophobic acrylic optic and polymethyl methacrylate chemically bonded haptics. The overall diKorean J Ophthalmol 2016;30(1):79-80 http://dx.doi.org/10.3341/kjo.2016.30.1.79

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors

BACKGROUND The purpose of this study was to assess the risk of intraocular contamination caused by intraocular lens (IOL) insertion with injectors by observing the dynamics of an ophthalmic viscosurgical device (OVD). METHODS Each type of injector was equipped with a colored OVD and IOL, and a 2 mm length from the tip of the cartridge was replaced with a colored OVD. The various combinations ...

متن کامل

The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery

PURPOSE The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. METHODS Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion dat...

متن کامل

Spontaneous fracture of an implanted posterior chamber intraocular lens.

PURPOSE Spontaneous fracture of an intraocular lens (IOL) haptic is a rare complication of cataract surgery. The authors report a case of spontaneous fracture of an implanted posterior chamber IOL. CASE Five years ago, a 12-year-old patient underwent linear lens extraction, posterior capsulotomy, and anterior vitrectomy due to traumatic cataract and received a polymethyl methacrylate (PMMA) b...

متن کامل

Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial.

AIM To compare characteristics of preloaded and non-preloaded intraocular lens (IOL) delivery systems during IOL delivery procedures. METHODS Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including iSert250 NC60 (NC60), EnVista MX60 (MX60), AcrySof IQ SN60WF (SN60WF), TECNIS ZCB00 (ZCB00), and TECNIS PCB00 (PCB00)...

متن کامل

Late-onset capsular bag distension syndrome following cataract surgery

A 74-year-old man presented to the ophthalmology outpatient clinic with reduced visual acuity and increasing haziness of vision in his left eye over several months. Seven years previously he had undergone uneventful cataract surgery with phacoemulsification and insertion of a posterior chamber lens (+14.5 dioptres Alcon MA60BM, 6.0 mm optic) in the same eye. There had been no postoperative comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2016