Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery.

نویسندگان

  • J J Vos
  • A F Kalmar
  • M M R F Struys
  • R J Porte
  • J K G Wietasch
  • T W L Scheeren
  • H G D Hendriks
چکیده

BACKGROUND The Masimo Radical 7 (Masimo Corp., Irvine, CA, USA) pulse co-oximeter(®) calculates haemoglobin concentration (SpHb) non-invasively using transcutaneous spectrophotometry. We compared SpHb with invasive satellite-lab haemoglobin monitoring (Hb(satlab)) during major hepatic resections both under steady-state conditions and in a dynamic phase with fluid administration of crystalloid and colloid solutions. METHODS Thirty patients undergoing major hepatic resection were included and randomized to receive a fluid bolus of 15 ml kg(-1) colloid (n=15) or crystalloid (n=15) solution over 30 min. SpHb was continuously measured on the index finger, and venous blood samples were analysed in both the steady-state phase (from induction until completion of parenchymal transection) and the dynamic phase (during fluid bolus). RESULTS Correlation was significant between SpHb and Hb(satlab) (R(2)=0.50, n=543). The modified Bland-Altman analysis for repeated measurements showed a bias (precision) of -0.27 (1.06) and -0.02 (1.07) g dl(-1) for the steady-state and dynamic phases, respectively. SpHb accuracy increased when Hb(satlab) was <10 g dl(-1), with a bias (precision) of 0.41 (0.47) vs -0.26 (1.12) g dl(-1) for values >10 g dl(-1), but accuracy decreased after colloid administration (R(2)=0.25). CONCLUSIONS SpHb correlated moderately with Hb(satlab) with a slight underestimation in both phases in patients undergoing major hepatic resection. Accuracy increased for lower Hb(satlab) values but decreased in the presence of colloid solution. Further improvements are necessary to improve device accuracy under these conditions, so that SpHb might become a sensitive screening device for clinically significant anaemia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Invasive versus noninvasive hemoglobin measurement by pulse CO-Oximeter in neonates admitted to NICU

Background Total haemoglobin measurement (tHb) is one of the most commonly performed laboratory tests in patients admitted to the neonatal intensive care unit (NICU). Non invasive haemoglobin measurement is possible. In neonates this method can reduce iatrogenic blood loss. Studies performed in adults to compare haemoglobin (Hb) obtained with the use of non-invasive Hb monitor and laboratory me...

متن کامل

Accuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid

Context Measurement of blood haemoglobin (Hb) concentration by pulse oximetry (SpHb) could be of value to determine when erythrocytes should be transfused during surgery, but the effect of infusion fluids on the results is unclear. Objective To study the effect of crystalloid and colloid fluid on the accuracy (bias) and precision of SpHb to indicate the venous Hb concentration in volunteers. De...

متن کامل

Effects of cardiopulmonary bypass on the accuracy of non-invasive hemoglobin measurement by pulse co-oximetry

Introduction A non-invasive continuous measurement of hemoglobin (Hb) by pulse co-oximetry (SpHb) using Radical-7 (Masimo Corporation, CA, USA) is a newly developed method of measuring total Hb concentration. Previously, the accuracy of SpHb in clinical settings was reported (1). However, it has been also reported that SpHb has poor correlation with arterial Hb after cardiac surgery (2). Here w...

متن کامل

Accuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid: Retraction.

CONTEXT Measurement of blood haemoglobin concentration by pulse oximetry could be of value in determining when erythrocytes should be transfused during surgery, but the effect of infusion fluids on the results is unclear. OBJECTIVE To study the effect of crystalloid and colloid fluid on the accuracy (bias) and precision of pulse oximetry haemoglobin estimation to indicate the venous haemoglob...

متن کامل

The Effect of Cardiopulmonary Bypass on the Accuracy of Non-Invasive Hemoglobin Measurement by Pulse Co- Oximetry

Background: A non-invasive continuous measurement of hemoglobin (Hb) by pulse co-oximetry (SpHb) using Radical-7® (Masimo Corporation, CA, USA) is a newly developed method of measuring total Hb concentration. Previously, the accuracy of SpHb in clinical settings was reported (1). However, it has been also reported that SpHb has poor correlation with arterial Hb after cardiac surgery (2). Here w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 109 4  شماره 

صفحات  -

تاریخ انتشار 2012