BACKGROUND The ProSeal Laryngeal Mask Airway (PLMA) (Laryngeal Mask Company, Henley-on-Thames, United Kingdom) is a new laryngeal mask with a modified cuff designed to improve its seal and a drain tube for gastric tube placement. Similarly, the Laryngeal Tube Suction (LTS) (VBM Medizintechnik Gmbh, Sulz a.N, Germany) is a new laryngeal tube that also has an additional channel for gastric tube placement. This study compared the placement and functions of these two devices. METHODS One hundred fifty patients undergoing general anesthesia for elective surgery were randomly allocated to the PLMA (n = 75) or LTS (n = 75). Oxygenation and ventilation, ease of insertion, fiberoptic view, oropharyngeal leak pressure, ventilatory data, ease of gastric tube insertion, and postoperative airway morbidity were determined. RESULTS After successful insertion of the devices in 96% of patients with the PLMA and in 94.4% with the LTS it was possible to maintain oxygenation, ventilation, and respiratory mechanics during the entire duration of surgery. Successful first and second attempt insertion rates were 57 patients (76%) and 15 patients (20%), respectively, for the PLMA and 60 patients (80%) and 11 patients (14.6%), respectively, for the LTS. Airway placement was unsuccessful with the PLMA in three patients and with the LTS in four patients. Time to achieve an effective airway was 36 +/- 24 s with the PLMA versus 34 +/- 25 s with the LTS. Gastric tube insertion was possible in 97.3% of patients with the PLMA and in 96% with the LTS. CONCLUSIONS With respect to both physiologic and clinical function, the PLMA and LTS are similar and either device can be used to establish a safe and effective airway in mechanically ventilated anesthetized adult patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gastroesophageal regurgitation during anesthesia and controlled ventilation with six airway devices.

STUDY OBJECTIVE To investigate the frequency of gastroesophageal regurgitation and respiratory mechanics during positive pressure ventilation using 5 supraglottic devices or an endotracheal tube (ETT). DESIGN Prospective, randomized study. SETTING Operating rooms in a university-affiliated hospital. PATIENTS 180 ASA physical status I and II patients, aged 18 to 65 years old, who underwent...

متن کامل

A comparison between Laryngeal Tube Suction II Airway and Proseal Laryngeal Mask Airway in laparascopic surgery.

This was a prospective randomized study comparing the ease of insertion, haemodynamic changes, quality of airway seal, oxygenation and ventilation parameters and complications between Laryngeal Tube Suction II (LTS II) with Proseal Laryngeal Mask Airway (PLMA), both are supraglottic airway incorporated with gastric passage. Fifty-four ASA I and II patients were randomly allocated to receive eit...

متن کامل

Randomized crossover comparison of ProSeal Laryngeal Mask Airway with Laryngeal Tube Sonda during anaesthesia with controlled ventilation.

BACKGROUND The Laryngeal Tube Sonda (LTS) is a supraglottic airway which, like the ProSeal Laryngeal Mask Airway (PLMA), incorporates a drain tube. We compared the performances of LTS and PLMA during controlled ventilation anaesthesia. METHODS The devices were studied in 32 ventilated patients by randomized crossover trial. Primary outcome was airway seal pressure. Secondary outcomes included...

متن کامل

Randomized crossover comparison of the proseal with the classic laryngeal mask airway in unparalysed anaesthetized patients.

BACKGROUND The ProSeal is a wire-reinforced laryngeal mask airway with an additional drain tube that leads to the distal tip of the laryngeal cuff. The design should improve the seal with the larynx. METHODS The ProSeal and classic laryngeal mask airways were compared in 180 patients in a randomized crossover study. Patients were anaesthetized without neuromuscular blocking drugs. RESULTS T...

متن کامل

Comparison of the Incidence of Sore Throat and Hemodynamic Changes in ‎Airway Management by Macintosh, Glideoscope Laryngoscope and ‎Laryngeal Mask Airway Techniques: Randomized Controlled Trial

Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway  techniques in elective surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 101 2  شماره 

صفحات  -

تاریخ انتشار 2004