The implantable cardioverter defibrillator.

نویسندگان

  • M Glikson
  • P A Friedman
چکیده

Implantable cardioverter defibrillators (ICDs) have evolved from the treatment of last resort to the gold standard therapy for patients at high risk for ventricular tachyarrhythmias. High-risk patients include those who have survived life-threatening arrhythmias, and individuals with cardiac diseases who are at risk for such arrhythmias, but are symptomless. Use of an ICD will affect the patient's quality of life. Some drugs can substantially affect defibrillator function and efficacy, and possible drug-device interactions should be considered. Patients with ICDs may encounter cell phones, antitheft detectors, and many other sources of potential electromagnetic Interference. In addition to treating ventricular tachyarrhythmias, new defibrillators provide full featured dual chamber pacing, and could treat atrial arrhythmias, and congestive heart failure by means of biventricular pacing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

تأثیر آموزش مبتنی بر الگوی خودمراقبتی اورم بر توان خودمراقبتی بیماران دارای دفیبریلاتور قلبی قابل کاشت (ICD)

  Background & Aim: Several studies have shown that the self-care activity of patients with implantable cardioverter defibrillator is inadequate. This study was conducted to assess the effect of an educational program based on the Orem’s self-care model in self-care ability of the patients .   Methods & Materials: This clinical trial was conducted among 66 patients with implantable cardiove...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lancet

دوره 357 9262  شماره 

صفحات  -

تاریخ انتشار 2001