Asphericity of the anterior human cornea with different corneal diameters.
نویسندگان
چکیده
PURPOSE To measure the anterior corneal asphericity (Q) with different corneal diameters. SETTING Department of Physics (Optometry), University of Minho, Braga, Portugal. METHODS Thirty-six eyes of 36 patients were evaluated using a videokeratoscope, and the Q-values were recorded. Topographic data were also analyzed using Vol-CT 6.89 software (Sarver & Associates, Inc) to obtain the Q-values with different corneal diameters (3.0 mm, 4.0 mm, 5.0 mm, 6.0 mm, and 7.0 mm). Variable Q models of corneal sagittal height were compared against models assuming constant Q-values obtained with the Medmont E300 videokeratoscope (Medmont Pty. Ltd.) and a standard Q model of -0.26. RESULTS The peripheral rate of change in corneal Q with different corneal diameters increased as corneal astigmatism increased. As a result, differences in the sagittal height between the constant model and variable model were evident beyond the central 3.0 mm area. There were significant differences between low and high astigmatic corneas in Q-values measured by the Medmont along the flattest meridian (P = .004) and Q-values obtained with Vol-CT software with a 7.0 mm corneal diameter (P = .026). CONCLUSIONS There were differences in sagittal corneal height calculations considering constant or variable models of Q. Concern arises when surgical interventions depend on corneal Q-values to predict the outcomes. Surgeons should be aware which procedure is behind Q computing by different corneal topographers and that a constant Q-value cannot reflect the actual shape of the cornea as significant departures from the actual sagittal height can arise depending on which Q-value is assumed.
منابع مشابه
The shape of the anterior and posterior surface of the aging human cornea
PURPOSE To determine the shape and astigmatism of the posterior corneal surface in a healthy population with age, using Scheimpflug photography corrected for distortion due to the geometry of the Scheimpflug imaging system and the refraction of the anterior corneal surface. METHODS Scheimpflug imaging was used to measure in six meridians the cornea of the right eye of 114 subjects, ranging in...
متن کاملCorneal Asphericity Changes after Implantation of Intrastromal Corneal Ring Segments in Keratoconus
Keratoconus is a progressive corneal thinning of unknown cause in which the cornea assumes a conical shape, with progressive irregular astigmatism and deterioration of visual acuity. The normal anterior corneal surface is prolate, and it could be described as conic (flattening of the radius of curvature from the apex toward the periphery)1. In keratoconus corneas, the steepening of the central ...
متن کاملChanges in corneal asphericity after laser refractive surgery, including reflection losses and nonnormal incidence upon the anterior cornea.
We tested the effects on laser ablation of reflection losses and nonnormal incidence on the anterior cornea. We measured presurgical and postsurgical corneal asphericity in 94 myopic eyes, comparing it with the corneal asphericity predicted by the Munnerlyn formula, modified or not, with an adjustment factor that takes into account the two effects mentioned above. The predictive power of the ex...
متن کاملCorneal Spherical Aberration and Corneal Asphericity after Small Incision Lenticule Extraction and Femtosecond Laser-Assisted LASIK
PURPOSE To investigate corneal spherical aberration and corneal asphericity after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). METHODS This study enrolled 70 patients having SMILE and 64 subjects receiving FS-LASIK. The preoperative spherical equivalent (SE) was -5.83 ± 1.23 diopters (D) and -6.20 ± 1.52 D, respectively. T...
متن کاملCorneal asphericity in eye bank eyes implanted with the intrastromal corneal ring.
OBJECTIVE To evaluate the effects of the intrastromal corneal ring, a device developed to reduce myopia, on corneal asphericity in a large set of eye bank eyes. METHODS Forty-one deturgesced eye bank eyes were implanted with intrastromal corneal rings of five different thicknesses, ranging from 0.25 mm to 0.45 mm. Corneal asphericity, before and after implantation, was examined using two diff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 33 3 شماره
صفحات -
تاریخ انتشار 2007