Does degree of the pelvic deformity affect the accuracy of computed tomography-based hip navigation?
نویسندگان
چکیده
Although some navigation systems have been used for improvement of component positioning, there have been few reports regarding cases of severe pelvic deformity. We performed a retrospective review of 25 cases of total hip arthroplasty with a computed tomography-based navigation system in patients with severe pelvic deformities and estimated acetabular component position and angle between severe deformity group and mild dysplastic group as a control. There were no significant differences in accuracy of navigation system between 2 groups in terms of 3-dimensional component position or angle. Accuracy of computed tomography-based hip navigation does not depend on the degree of pelvic deformity, and this system is also useful to identify acetabular orientation and for precise component implantation in cases of pelvic deformity.
منابع مشابه
Computed tomography assessment of image-free navigation-assisted cup placement in THA in an Asian population.
The authors hypothesized that an image-free navigation system would be more accurate than postoperative 3-dimensional (3-D) reconstructed computed tomography (CT) for acetabular cup inclination and anteversion during total hip arthroplasty (THA) in an Asian population. Eighty-one THAs were performed in 72 patients using the OrthoPilot image-free navigation system (B. Braun Aesculap, Tuttlingen,...
متن کاملThe Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications
In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon....
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملبررسی میزان چرخش در شکستگی شفت فمور پساز نیلگذاری در 70 بیمار
Background: Rotational deformity after intramedullary nailing is a well-known complication. Femoral malrotation is the most common form of mal::::union:::: but it is underrecognized in part because of the difficulty in accurately assessing rotation as well as the variation that exists in normal anatomy. The aim of this study was to evaluate femoral malrotation following intramedullary nailing o...
متن کاملComputed tomography-based surgical navigation for hip arthroplasty.
Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 27 9 شماره
صفحات -
تاریخ انتشار 2012