Three-dimensional white light camera to aid lipoabdominoplasty: a pilot project.
نویسندگان
چکیده
BACKGROUND Historically, torso obesity has been difficult to quantify. Digital technology has recently encroached into body contouring surgery but has not been developed by surgeons to aid with their anatomical mandates. METHODS For 3 years, the authors tested a three-dimensional digital body camera that used nonintrusive white light phase profilometry to produce a "point cloud" image of the subject. The result of the 2-minute scan process was an accurate three-dimensional body model of the subject, consisting of over 1.2 million surface points. The point cloud was compressed to provide programmable measurement extraction profiles that automatically extracted linear and circumferential measurements. Subjects were scanned and anthropometrically measured preoperatively and at 3, 6, and 9 months postoperatively. Seven circumferential measures (waist, hips, abdomen, bilateral thighs, and bilateral knees) were collected. RESULTS Fifty-two lipoabdominoplasty subjects participated in this pilot project. Lin's correlation coefficient was used to compare concordance between camera scan and anthropometric measurements and to compare the camera's reliability. When Lin's correlation coefficient was applied to our data, the composite Lin's correlation coefficient comparisons between the camera and anthropometric measurements were 0.9663 ± 0.0035 preoperatively and 0.9634 ± 0.0027 postoperatively. Anthropometric hip, waist, abdominal, and thigh circumferences all correlated closely with digital white light technology preoperatively (waist, 0.8602; hip, 0.6705; and abdomen, 0.8033) and improved at 6 months postoperatively (waist, 0.9197; and abdomen, 0.8031). CONCLUSION In this project, Lin's correlation coefficient indicated that the digital camera was as accurate as and more efficient than anthropometric measuring for circumferential measurements.
منابع مشابه
“It’s About the Idea Hitting the Bull’s Eye”: How Aid Effectiveness Can Catalyse the Scale-up of Health Innovations
Background Since the global economic crisis, a harsher economic climate and global commitments to address the problems of global health and poverty have led to increased donor interest to fund effective health innovations that offer value for money. Simultaneously, further aid effectiveness is being sought through encouraging governments in low- and middle-income countries (LMICs) to strengthen...
متن کاملEffect of digital elevation model’s resolution in producing flood hazard maps
Flooding is one of the most devastating natural disasters occurring annually in the Philippines. A call for a solution for this malady is very challenging as well as crucial to be addressed. Mapping flood hazard is an effective tool in determining the extent and depth of floods associated with hazard level in specified areas that need to be prioritized during flood occurrences. Precedent to the...
متن کاملThree Dimensional Analysis of Flow Past a Solid-Sphere at Low Reynolds Numbers with the Aid of Body Fitted Coordinates
In this paper, the flow-field of an incompressible viscous flow past a solid-sphere at low Reynolds numbers (up to 270) is investigated numerically. In order to extend the capabilities of the finite volume method, the boundary (body) fitted coordinates (BFC) method is used. Transformation of the partial differential equations to algebraic relations is based on the finite-volume method with coll...
متن کاملThree Dimensional Analysis of Flow Past a Solid-Sphere at Low Reynolds Numbers with the Aid of Body Fitted Coordinates
In this paper, the flow-field of an incompressible viscous flow past a solid-sphere at low Reynolds numbers (up to 270) is investigated numerically. In order to extend the capabilities of the finite volume method, the boundary (body) fitted coordinates (BFC) method is used. Transformation of the partial differential equations to algebraic relations is based on the finite-volume method with coll...
متن کاملThree-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Plastic and reconstructive surgery
دوره 127 4 شماره
صفحات -
تاریخ انتشار 2011