Quantitation of mitral valve tenting in ischemic mitral regurgitation by transthoracic real-time three-dimensional echocardiography.

نویسندگان

  • Nozomi Watanabe
  • Yasuo Ogasawara
  • Yasuko Yamaura
  • Takahiro Kawamoto
  • Eiji Toyota
  • Takashi Akasaka
  • Kiyoshi Yoshida
چکیده

OBJECTIVES We sought to investigate the geometric changes of the mitral leaflets and annulus, clarify the maximum tenting site of the leaflets, and quantify the valve tenting in ischemic mitral regurgitation (MR) using three-dimensional (3D) echocardiography. BACKGROUND Although the understanding of the mechanisms of ischemic MR has advanced recently, the geometric changes of the mitral leaflets and annulus have been assessed by two-dimensional echocardiography in the clinical setting, despite the unique configuration of the leaflets and annulus. METHODS Utilizing real-time 3D echocardiography, we obtained transthoracic volumetric images in 12 patients with ischemic MR presenting with global left ventricular dysfunction and in 10 controls. Original software was used to crop the 3D data into 18 radial planes, and we marked the mitral annulus and leaflets in each plane in mid-systole. The 3D images of the leaflets and annulus were reconstructed for the quantitative measurements. RESULTS In ischemic MR, the annulus flattened with apparent tenting of the leaflets. Maximum and mean tenting length were longer and tenting volume was larger in ischemic MR than control subjects (maximum tenting length: 9.8 +/- 2.0 mm vs. 3.1 +/- 1.2 mm, p < 0.0001, mean tenting length: 3.7 +/- 0.9 mm vs. 0.7 +/- 0.5 mm, p < 0.0001, tenting volume: 4.09 +/- 1.22 ml vs. 0.45 +/- 0.29 ml, p < 0.0001). The maximum tenting site was located in anterior leaflet in all patients. CONCLUSIONS We clearly demonstrated 3D geometric deformity of the mitral leaflets and annulus in ischemic MR using novel software for creating images by 3D echocardiography. This technique will be helpful in making a proper decision for the surgical strategy in each patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification and localization of mitral valve tenting in ischemic mitral regurgitation using real-time three-dimensional echocardiography.

OBJECTIVE Ischemic mitral regurgitation (IMR) results from a variable combination of annular dilatation and remodeling of the subvalvular apparatus. Current surgical techniques effectively treat annular dilatation, but methods for addressing subvalvular remodeling have not been standardized. An effective technique for determining the extent of subvalvular remodeling could improve surgical resul...

متن کامل

Multiplane two-dimensional versus real time three-dimensional transesophageal echocardiography in ischemic mitral regurgitation.

OBJECTIVES Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has been suggested to be a valuable technique for the evaluation of the mechanisms of ischemic mitral regurgitation (IMR). Studies comparing multiplane two-dimensional (2D) with 3D TEE reconstruction of the mitral valve using the new mitral valve quantification (MVQ) software are lacking. We undertook a pros...

متن کامل

Transient severe reversible functional mitral regurgitation: a three-dimensional transoesophageal perspective.

Mrs B, a 49-year-old female, was referred to our institution for severe mitral regurgitation. Transthoracic echocardiography showed only a moderate organic mitral regurgitation, but a transient severe reversible functional mitral regurgitation was observed during transoesophageal echocardiography (TEE). Three-dimensional TEE clearly demonstrated the functional nature of the regurgitation with a...

متن کامل

Real-time three-dimensional transthoracic echocardiography.

BACKGROUND Complex anatomy of intra-cardiac structures requires spatial orientation of image in three dimensions for better understanding and enhanced image interpretation. We evaluated the feasibility and efficacy of the emerging 'real-time three-dimensional transthoracic echocardiography' technique for comprehensive assessment of cardiac anatomy, physiology, pathomorphology and pathophysiolog...

متن کامل

Effect of transcatheter aortic valve replacement on the mitral valve apparatus and mitral regurgitation: real-time three-dimensional transesophageal echocardiography study.

BACKGROUND The effect of transcatheter aortic valve replacement (TAVR) on the mitral valve apparatus and factors influencing the reduction of mitral regurgitation with or without mitral leaflet tethering after TAVR are poorly understood. The present 3-dimensional (3D) transesophageal echocardiography study aimed to elucidate early changes further in the structure and function of the mitral valv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 45 5  شماره 

صفحات  -

تاریخ انتشار 2005