Arteriovenous shunt visualization in arteriovenous malformations with arterial spin-labeling MR imaging.

نویسندگان

  • R L Wolf
  • J Wang
  • J A Detre
  • E L Zager
  • R W Hurst
چکیده

BACKGROUND AND PURPOSE A reliable quantitative technique for measuring arteriovenous (AV) shunt in vascular malformations is not currently available. Here, we evaluated the hypothesis that continuous arterial spin-labeled (CASL) perfusion MR imaging can be used to detect and measure AV shunt in patients with arteriovenous malformations (AVMs). MATERIALS AND METHODS CASL perfusion MR imaging was performed in 7 patients with AVMs. Semiquantitative AV shunt estimates were generated based on a thresholding strategy by using signal-intensity difference (DeltaM) images to avoid potential errors in cerebral blood flow (CBF) calculation related to abnormal transit times and nonphysiologic blood-tissue water exchange in and around the AVMs. The potential for measuring CBF in regions distant from and near the AVM was explored, as was the relationship of CBF changes related to the size of the shunt. RESULTS In all 7 cases, striking increased intensity was seen on CASL perfusion DeltaM maps in the nidus and venous structures draining the AVM. Shunt estimates ranged from 30% to 0.6%. Mean CBF measurements in structures near the AVMs were not significantly different from the contralateral measurements. However, CBF in adjacent ipsilateral white matter increased relative to the contralateral side as the percent shunt increased (P = .02). Cortical gray matter CBF Delta (contralateral-ipsilateral) values demonstrated the same effect, but the correlation was weak and not significant. Thalamic CBF decreased ipsilaterally with increasing percent AV shunt (P = .01), indicating a possible steal effect. Basal ganglia Delta values showed little change in CBF with the size of the AV shunt. CONCLUSION CASL perfusion MR imaging can demonstrate AV shunting, providing high lesion conspicuity and a novel means for evaluating AVM physiology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial spin labeling perfusion-weighted MRI for long-term follow-up of a cerebral arteriovenous malformation after stereotactic radiosurgery

We present a longitudinal series of arterial spin-labeling magnetic resonance imaging (ASL-MRI) in a patient with cerebral arteriovenous malformations (AVMs) treated by stereotactic radiosurgery (SRS). Pretreatment ASL-MRI showed high signal intensity in both the nidus and draining veins, and the latter signal abnormality gradually moved proximally by 14 months after SRS. At 24 months, the sign...

متن کامل

MR Visualization of Spinal Dural Arterio-Venous Fistula Using T2-Weighted 3D SPACE—A Spin-Echo Technique

Spinal dural arteriovenous fistulas (SDAVF) account for about 70% of all spinal AV shunts. We report on a 56-year-old male patient with progressive neurological symptoms. Preand post-contrast MR imaging of the spine, including contrast-enhanced MR angiography was done on a 1.5 T MR scanner. In addition a special (pre-contrast) 3D turbo-spin-echo sequence with variable flip angle evolution (SPAC...

متن کامل

Brain perfusion territory imaging: methods and clinical applications of selective arterial spin-labeling MR imaging.

The ability to visualize perfusion territories in the brain is important for many clinical applications. The aim of this overview is to highlight the possibilities of selective arterial spin-labeling (ASL) magnetic resonance (MR) imaging techniques in the assessment of the perfusion territories of the cerebral arteries. In the past decade, the optimization of selective ASL MR techniques to imag...

متن کامل

Time-resolved noncontrast enhanced 4-D dynamic magnetic resonance angiography using multibolus TrueFISP-based spin tagging with alternating radiofrequency (TrueSTAR).

PURPOSE The goal of this study was to introduce a new noncontrast enhanced 4D dynamic MR angiography (dMRA) technique termed multibolus TrueFISP-based spin tagging with alternating radiofrequency (TrueSTAR). METHODS Multibolus TrueFISP-based spin tagging with alternating radiofrequency was developed by taking advantage of the phenomenon that the steady-state signal of TrueFISP is minimally di...

متن کامل

Intracranial Dural Arteriovenous Fistula: Preliminary Report of Arterial Spin Labeling

Purpose: We report the results of applying arterial spin labeling (ASL) to intracranial dural arteriovenous fistula (DAVF). Methods: Sixteen patients with angiographically confirmed DAVF underwent ASL on a clinical 1.5 T or 3 T MR system. ASL was performed by Q2TIPS (second version of quantitative imaging of perfusion by using a single subtraction MRI pulse sequence with thin-slice TI1 periodic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2008