Computer navigation and fixator-assisted femoral osteotomy for correction of malunion after periprosthetic femur fracture.

نویسندگان

  • Daniel O Kendoff
  • Austin T Fragomen
  • Andrew D Pearle
  • Mustafa Citak
  • S Robert Rozbruch
چکیده

Periprosthetic femoral fracture post-total knee arthroplasty can lead to malunion. This may lead to abnormal force transmission and accelerated wear of the prosthesis. Accurate femoral deformity correction depends on the combined correction of the mechanical axis alignment and the lateral distal femoral angle. Modern external fixation correction devices allow for simultaneous gradual corrections in multiple planes through one osteotomy site. Despite the accuracy of the devices, technical failures occur and are typically due to difficulty in assessing the exact intraoperative correction. Furthermore, conventional intraoperative measurements display high interobserver and intraobserver variations. Computer navigation has demonstrated great accuracy. Combining a mechanical corrective device and navigation should allow for increased precision and dynamic control intraoperatively. The current authors report on a clinical application of a novel minimally invasive fixator-assisted correction of a posttraumatic distal femoral varus deformity after total knee arthroplasty with combined navigated measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-Stage Femoral Osteotomy and Computer-Assisted Navigation Total Knee Arthroplasty for Osteoarthritis in a Patient with Femoral Subtrochanteric Fracture Malunion

Extra-articular femoral deformity in total knee arthroplasty (TKA) is realigned by either intra-articular correction or extra-articular osteotomy. The more distant the deformity is away from knee joint, the more likely it is corrected by the former method. No report described the use of antegrade cephalomedullary femoral nail to fix the osteotomy followed by computer-assisted navigation TKA. Th...

متن کامل

Deformity Correction by Femoral Supracondylar Dome Osteotomy with Retrograde Intramedullary Nailing in Varus Deformity of the Distal Femur after Pathologic Fracture of Giant Cell Tumor

Angular deformities of the distal femur occur in congenital diseases or due to acquired causes, such as malunion after a fracture of the distal femur. Angular deformities of the lower extremities affect the mechanical axis, causing changes in the weight pressure on the articular surface. As a result, angular deformities quicken the progression of osteoarthritis. Therefore, correction of deformi...

متن کامل

Corrective osteotomy for combined shortening and rotational malunion of the femur.

Rotational malunion of femoral fractures after intramedullary fixation is surprisingly common. Wiss et al (1986) reported from 10#{176} to 30#{176} external rotational deformity in 7% of 1 12 patients and Br#{226}ten,Terjesen and Rossvoll (1993) found that 21 of 1 10 fractures healed with over 15#{176} deformity. Rotation is often combined with shortening, especially in oblique or comminuted fr...

متن کامل

Treatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails

  Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...

متن کامل

Shape memory embracing fixator for Vancouver type B and type C periprosthetic femoral fractures.

The purpose of this study was to analyze clinical and radiographical results of a group of patients with periprosthetic femoral fractures treated with the shape memory embracing fixator. We retrospectively reviewed twelve patients in whom a total of twelve periprosthetic femoral fractures were treated with the shape memory embracing fixator between August 2004 and February 2013. The patients we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2010