Accurate image reconstruction from few-view and limited-angle data in diffraction tomography.
نویسندگان
چکیده
We present a method for obtaining accurate image reconstruction from highly sparse data in diffraction tomography (DT). A practical need exists for reconstruction from few-view and limited-angle data, as this can greatly reduce required scan times in DT. Our method does this by minimizing the total variation (TV) of the estimated image, subject to the constraint that the Fourier transform of the estimated image matches the measured Fourier data samples. Using simulation studies, we show that the TV-minimization algorithm allows accurate reconstruction in a variety of few-view and limited-angle situations in DT. Accurate image reconstruction is obtained from far fewer data samples than are required by common algorithms such as the filtered-backpropagation algorithm. Overall our results indicate that the TV-minimization algorithm can be successfully applied to DT image reconstruction under a variety of scan configurations and data conditions of practical significance.
منابع مشابه
Improved Backpropagation Algorithms by Exploiting Data Redundancy in Limited-Angle Diffraction Tomography
Filtered backpropagation (FBPP) is a well-known technique used in Diffraction Tomography (DT). For accurate reconstruction of a complex-valued image using FBPP, full 360◦ angular coverage is necessary. However, it has been shown that by exploiting inherent redundancies in the projection data, accurate reconstruction is possible with 270◦ coverage. This is called the minimal-scan angle range. Th...
متن کاملAccurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Abstract In practical applications of tomographic imaging, there are often challenges for image reconstruction due to under-sampling and insufficient data. In computed tomography (CT), for example, image reconstruction from few views would enable rapid scanning with a reduced x-ray dose delivered to the patient. Limited-angle problems are also of practical significance in CT. In this work, we d...
متن کاملTGV sinogram inpainting for limited angle tomography
X-ray computed tomography (CT) plays a very important role in daily biomedical practice for diagnosis and therapy, and in materials science for accurate data analysis and quality control. Besides accurate and robust image reconstruction, there is a growing interest in methods for limited angle tomography. The idea is to reduce the X-ray dose delivered to patients or to cope with physical angle ...
متن کاملPhotoacoustic image reconstruction from few-detector and limited-angle data
Photoacoustic tomography (PAT) is an emerging non-invasive imaging technique with great potential for a wide range of biomedical imaging applications. However, the conventional PAT reconstruction algorithms often provide distorted images with strong artifacts in cases when the signals are collected from few measurements or over an aperture that does not enclose the object. In this work, we pres...
متن کاملℓ0 Gradient Minimization Based Image Reconstruction for Limited-Angle Computed Tomography
In medical and industrial applications of computed tomography (CT) imaging, limited by the scanning environment and the risk of excessive X-ray radiation exposure imposed to the patients, reconstructing high quality CT images from limited projection data has become a hot topic. X-ray imaging in limited scanning angular range is an effective imaging modality to reduce the radiation dose to the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 25 7 شماره
صفحات -
تاریخ انتشار 2008